( Manufacturer Part Number: 239165 ), ( Part Type: Spray ), ( UPC: 615311287455 )
Use the final average to represent amount of spray.
The temperature of pressure barrel should be kept in 47 1 degree, brine 35 degree. Sample identification mark should be marked on the bottom of test piece.
Any costs incurred because of incorrect or un deliverable address should be undertaken by buyer. The material is stainless steel.
Blunt material is required, it required that the itself cannot be corroded, and can not affect corrosion test.
If there is any problems, please asap. Hope for your understanding.
Spray liquid should be collected at least 16 hours, an average per hour can 2ml to 1ml solution.
Each sample cannot be in contact with other. Salt spray can't drop from one test piece to another.
The test liquid dropped from piece cannot flow back to salt bucket again for.
Use the salt spray test machine to sodium chloride solution surface of electric coating achieve purpose detection. Permutation of samples, the spray should be free to drop on all test pieces, preventing situation blocking.
The fog nozzle cannot spray test liquid directly to sample, solution at top of spraying chamber drop on piece. The concentration of sodium chloride solution should be maintained at 40 60g l.