
( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9140-DW-156 ), ( UPC: 095969413473 )
The Fluke 9140-DW-156 Calibration Dry Well is a mid-range product designed for precision calibration tasks. This dry well is equipped with a voltage input range of 115V, making it suitable for a wide range of electrical applications.
The Fluke 9140-DW-156 Calibration Dry Well features a spacious 156 cubic inches (2.56 liters) internal volume, providing ample space for large electrical devices or assemblies during calibration. This dry well is constructed with a sturdy, corrosion-resistant aluminum alloy, ensuring durability and longevity in various harsh environments.
Equipped with a removable, drainable base, the Fluke 9140-DW-156 Calibration Dry Well allows for easy cleaning and maintenance. The base is designed with a drain plug, allowing for quick and hassle-free draining of any fluids or debris. The base also includes a built-in vent to prevent the build-up of pressure and prevent damage to the device inside.
The Fluke 9140-DW-156 Calibration Dry Well is designed with a secure locking lid to ensure the safety of the device being calibrated. The lid features a gasket to create a tight seal, preventing the entry of moisture and contaminants, and ensuring a stable and accurate calibration environment.
In conclusion, the Fluke 9140-DW-156 Calibration Dry Well is a reliable and durable mid-range product that provides a stable and protected environment for calibration tasks. Its spacious internal volume, corrosion-resistant construction, and removable, drainable base make it an ideal choice for various electrical calibration applications.
Pros of buying a Fluke 9140-DW-156 Calibration Dry Well:1. Mid-range pricing: This Fluke model falls into the mid-range price category, making it an affordable option for many users who require a high-quality calibration dry well.
2. Durable construction: The Fluke 9140-DW-156 is built to last with a heavy-duty, corrosion-resistant stainless-steel construction.
3. Wide temperature range: The device can operate in a wide temperature range of -40 C to 85 C, making it suitable for various environments.
4. Accurate measurements: The Fluke 9140-DW-156 offers precise and reliable measurements, ensuring that calibrations are carried out accurately.
5. Easy to use: The device has a user-friendly interface and clear visual displays, making it easy for users to operate and read results.
Cons of buying a Fluke 9140-DW-156 Calibration Dry Well:1. Limited measurements: Compared to more expensive models, the Fluke 9140-DW-156 has a limited number of measurement capabilities, making it less versatile for certain applications.
2. Larger size: The device is relatively larger and heavier than some other models in its class, which may make it less portable for some users.
3. Limited power options: The Fluke 9140-DW-156 operates on 115V power, which may limit its use in areas with different voltage requirements.
Conclusion:The Fluke 9140-DW-156 Calibration Dry Well is a great option for users who require a reliable, mid-range calibration device with a wide temperature range and durable construction. While it has some limitations in terms of measurement capabilities and portability, its affordability and ease of use make it a popular choice for many users.
Recommendation:If you are looking for a mid-range calibration device with accurate measurements and a heavy-duty construction, the Fluke 9140-DW-156 is a solid choice. However, if you require more measurement capabilities or need a more portable device, you may want to consider other options in the market. Ultimately, the best choice will depend on your specific needs and budget.
C in the smaller wells. Fluke Calibration uses dry-wells every day in manufacturing and Calibration, know what makes a dry-well easy productive to use-which is exactly how users describe harts series of field. Use the display, calibrated to. This means less maintenance costs and down time when they do need Calibration.
C in the largest-diameter wells and. C or better and a uniformity of at least.
The software is written for windows and has a great graphical interface.
Despite its small size, this unit performs. Harts interface-it software let's you adjust set-points and ramp rates, log dry-well readings to a file, create an electronic strip chart, perform thermal switch testing with data collection.
Hart dry-wells are easy to calibrate. Its truly a unique innovation in dry-wells. Every dry-well is tested at harts factory, and unit comes with a Inst-traceable Calibration. The unit has a stability of.
At six pounds, its small enough to easily carry in one hand.
You should't have to pay extra for Calibration procedures hart performs anyway. C, as your reference, or use an external thermometer for maximum Calibration accuracy. In addition, the heating and cooling rate of each these dry-wells is adjustable from front panel, thermal switches can be checked for actuation testing, multiple-hole inserts are available a variety probe sizes.
Cr's-232 and interface-it software included easy to re calibrate Fluke Calibration 9140-DW-156 dry-well, mid-range field, no insert, 115v. Subscribe to our Fluke Calibration 9140-DW-156 dry-well, mid-range field, no insert, 115v brand: Fluke model number: 9140-DW-156ref no: 9140dw156 condition: Newark: 73 data sheet product and very portable accuracy. Add 24 for AK, hi, or pr.
The 9140 has a temperature range of 35 to 350. C, and it reaches its maximum in 12 minutes. With three removable inserts to choose from, the 9140 is as versatile it fast.