( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9170-A-156 ), ( UPC: 095969293846 )
The W-9170-INSA Fluke Calibration 9170 is a top-of-the-line multimeter designed for metrology applications. This 156-function digital multimeter (DMM) is equipped with advanced features that make it an essential tool for professionals in various industries, including electronics, manufacturing, and research.
The 9170-INSA is a 4 1/2-digit true RMS DMM that offers an impressive measurement range of DC 100 mV to 1000 V, AC 100 mV to 1000 V, and 1000 Hz to 60 MHz. It features a high input impedance of 100 G , which minimizes loading effects and ensures accurate readings, even on low-voltage sources.
One of the standout features of this multimeter is its automatic frequency range selection, which allows for easy and accurate measurement of AC signals. The 9170-INSA also includes a function for measuring capacitance, inductance, and resistance, making it a versatile tool for a wide range of tasks.
The 9170-INSA is built to last, with a rugged and water-resistant enclosure that can withstand harsh environments. It is powered by a 115V AC outlet, and its large backlit LCD display ensures easy readability, even in low-light conditions.
In addition, this multimeter is equipped with a comprehensive set of safety features, including overvoltage protection, overcurrent protection, and a cat III 600 V safety rating. It also includes a data hold function, which allows users to freeze the current reading on the display, and a peak hold function, which displays the maximum value of an AC waveform.
The W-9170-INSA Fluke Calibration 9170 is a highly accurate and reliable tool for metrology applications. Its advanced features, rugged design, and extensive safety features make it an excellent choice for professionals who require precision and reliability in their measurements.
The product code for this item is 095969293846, and it is available in the A-156 configuration. The 9170-INSA is backed by Fluke's industry-leading warranty, ensuring peace of mind for users who demand the best from their measurement tools.
Product: Fluke Calibration 9170-INSA, Model 156, Metrology 45C, 115V
Pros:1. High Accuracy: The Fluke Calibration 9170-INSA is known for its high accuracy, making it an excellent choice for calibration and measurement tasks in various industries.
2. Wide Temperature Range: It operates in a wide temperature range of -40 C to 85 C, making it suitable for use in various environmental conditions.
3. Versatility: This device can measure voltage, current, resistance, and frequency, making it a versatile tool for various electrical measurements.
4. Durable Design: The Fluke Calibration 9170-INSA has a rugged design, ensuring it can withstand harsh conditions in the field.
5. Built-in Data Logger: This feature allows users to store and analyze measurement data, making it easier to track trends and improve processes.
Cons:1. High Cost: The Fluke Calibration 9170-INSA is a high-end device, which means it comes with a premium price tag.
2. Complexity: The device might be too complex for beginners, as it requires advanced knowledge of electrical measurements.
3. Limited Portability: While it's rugged, its size and weight might make it less portable for some users.
4. Limited Battery Life: The device requires an external power source, which might be inconvenient for some users who need a portable power source.
Conclusion:The Fluke Calibration 9170-INSA is an excellent choice for professionals in various industries who require high-accuracy electrical measurements. Its wide temperature range, versatility, and rugged design make it an ideal tool for various applications. However, its high cost and complexity might be off-putting for some users. It's recommended to consider the specific needs of your application before making a purchase decision. If you can afford the premium price and have the necessary expertise, the Fluke Calibration 9170-INSA is an excellent investment. If you're looking for a more budget-friendly option, there are other devices available with similar functionalities but lower accuracy and performance.
C at the most commonly used temperatures to. All four model's come with an rs-232 serial interface and the model 9930, interface-it software. The Fluke Calibration 9170 series only gets better with metrology wells.
Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. 4mm loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too. The hart 9170 series is 160mm 6.
New analog and digital control techniques provide stability as good. The user interface can be configured to display in English, french, or Chinese. For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. The Fluke hart 9170 is stable to.
Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source. C, the Fluke Calibration 9170 delivers exceptional uncertainty budgets and is perfect for a variety of pharmaceutical other applications. And with dual-zone control, axial or vertical uniformity is as good. For hart scientific 9170 series metrology wells, hysteresis effects range from in zone.
The Fluke Calibration 9170 achieves lowest temperatures of series, reaching -45. C in normal room conditions. With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in. It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source?range.
Such performance doesn. Exist anywhere else outside of fluid baths. C in the cold units. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance. F button allows for easy switching of temperature units.
Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each. Both low-temperature units are table to. There is an automated. Switch test protocol that zeros in on the dead-band for thermal switches.
With axial uniformity of. C radial uniformity: uniformity is the difference in temperature between one well and another.
Stability: heat sources from Fluke Calibration have long been known as the most stable in world. Vertical gradients in these zones range from.
C over its full temperature range up to 140. C and has 160mm in diameter or smaller. Loading effects are as minimal. For even better accuracy, Fluke Calibration 9170 series metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations.
3 in deep to facilitate temperature of -45.
The cold units and provide radial uniformity of. 54 in, usually at the bottom of a well. Immersion depth: depth matters. Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator?internal control sensor based on readings from.
Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm. C over 60 It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats. This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator. And we utilize proprietary dual-zone controls.
All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate. The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from.
Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats. In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis.
C and radial uniformity of. Our specs aren. Just hopes or guidelines.
For metrology wells, loading effects are minimized the same reasons that axial gradients.
Add 24 for AK, hi, or pr. Temperature range from -45. CFO cold units Fluke Calibration 9170-A-156 metrology well calibrator, -45c, w 9170-insa, 115v. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large.
C over their full range.