( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9170CR156 )
The Fluke Calibration 9170-C-R-156 is a high-performance, versatile digital multimeter designed for metrology applications. This model, specifically the 9170-INSC 115V, is part of Fluke's renowned line of precision measuring instruments.
The 9170-C-R-156 is equipped with a 6.2-inch, high-resolution, color touchscreen display, providing clear and easy-to-read measurements. The multimeter supports a wide range of measurements, including DC voltage, AC voltage, DC current, resistance, and frequency, among others. It also features a 4-digit, 6000 count display for high accuracy and a built-in thermometer for temperature measurements.
This model is designed with metrology applications in mind, offering a number of advanced features. It includes a 12-bit analog-to-digital converter for high-precision measurements, as well as auto and user-defined calibration functions to ensure traceability and accuracy. The 9170-C-R-156 also includes a built-in data logger, allowing users to save and review measurement data, and a traceable calibration certificate is included with each unit.
The Fluke Calibration 9170-C-R-156 is built to withstand even the toughest industrial environments. It is rated for CAT III 600V safety, and its rugged construction includes a rubberized housing, impact-resistant display, and a keypad that is resistant to water and dust. The multimeter is also powered by an internal rechargeable battery, which can be charged using the included AC adapter.
In summary, the Fluke Calibration 9170-C-R-156 is a high-performance, versatile digital multimeter designed for metrology applications. It offers a wide range of measurements, advanced features, and is built to withstand even the toughest industrial environments. With its high accuracy, data logging capabilities, and traceable calibration certificate, this multimeter is an essential tool for any metrology lab or industrial facility.
The Fluke Calibration 9170-C-R-156 is a high-precision multifunction calibrator designed for use in metrology applications. Here are some pros and cons of purchasing this device:
Pros:1. Wide Range of Capabilities: The 9170-C-R-156 can perform a wide range of calibration tasks, including DC voltage, current, resistance, and power. This makes it a versatile tool for many different applications.
2. High Precision: With a measurement uncertainty of 0.002% or better, the 9170-C-R-156 is a highly precise instrument, ideal for calibrating other measurement devices.
3. Rugged Design: The device is built to withstand harsh environments, making it suitable for use in industrial settings.
4. User-Friendly Interface: The 9170-C-R-156 features a large, easy-to-read display and intuitive menus, making it simple to use even for those who are not familiar with calibration equipment.
Cons:1. High Cost: The 9170-C-R-156 is a high-end instrument, and its price reflects this. It may be too expensive for some budgets.
2. Complexity: While the user interface is intuitive, the device has a lot of features and capabilities, which can be overwhelming for some users.
3. Requires Regular Calibration: As a calibration tool, the 9170-C-R-156 requires regular calibration to ensure its own accuracy. This can add to the cost and time required to maintain the instrument.
In conclusion, the Fluke Calibration 9170-C-R-156 is a powerful and precise calibration tool that is ideal for use in metrology applications. Its wide range of capabilities, rugged design, and user-friendly interface make it a great choice for many users. However, its high cost and complexity may be a deterrent for some. Ultimately, the decision to purchase the 9170-C-R-156 should be based on the specific needs and budget of the user. If the device's capabilities and benefits outweigh its cost and complexity, it can be a valuable investment for any metrology lab or industrial setting.
C, the Fluke Calibration 9170 delivers exceptional uncertainty budgets and is perfect for a variety of pharmaceutical other applications. For even better accuracy, Fluke Calibration 9170 series metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations. And we utilize proprietary dual-zone controls. 54 in, usually at the bottom of a well.
The Fluke hart 9170 is stable to.
C and radial uniformity of. And with dual-zone control, axial or vertical uniformity is as good. New analog and digital control techniques provide stability as good.
Loading effects are as minimal. The hart 9170 series is 160mm 6. Immersion depth: depth matters.
The user interface can be configured to display in English, french, or Chinese. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate. Temperature range from -45. CFO cold units Fluke Calibration 9170-C-R-156 metrology well calibrator, -45c,w 9170-INSC,w ref, 115v. It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source.
Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too. For metrology wells, loading effects are minimized the same reasons that axial gradients. Even without a PC, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each.
The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from. 25 in diameter or smaller.
For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. Add 24 for AK, hi, or pr. Our specs aren. Just hopes or guidelines. The cold units and provide radial uniformity of.
All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. 3 in of immersion depth.
Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator. ?internal control sensor based on readings from. C over their full range.
Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. C over its full temperature range up to 140. C and has 160mm 6. All four model's come with an rs-232 serial interface and the model 9930, interface-it software. Stability: heat sources from Fluke Calibration have long been known as the most stable in world.
In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis. This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator. C over a 60mm 2.
Vertical gradients in these zones range from. With axial uniformity of. Such performance doesn. Exist anywhere else outside of fluid baths. The Fluke Calibration 9170 series only gets better with metrology wells.
C at the most commonly used temperatures to. With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in. There is an automated. Switch test protocol that zeros in on the. Dead-band for thermal switches. Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats.
Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source. For hart scientific 9170 series metrology wells, hysteresis effects range from. 3 in deep to facilitate temperature of -45.
The Fluke Calibration 9170 achieves lowest temperatures of series, reaching -45. C in normal room conditions. Both low-temperature units are table to. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance. Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm 1.
This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats. F button allows for easy switching of temperature units.
C radial uniformity: uniformity is the difference in temperature between one well and another. C in the cold units.
For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large.