  3. FLUKE CALIBRATION 9171-C-156

FLUKE CALIBRATION 9171-C-156 Metrology 095969294164 30C 9171-INSC 115V

9171-c-156 Fluke Calibration Metrology Well 30c

( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9171-C-156 ), ( UPC: 095969294164 )

Review FLUKE CALIBRATION 9171 156 Metrology Well 30c 115v

The Fluke Calibration 9171-C-156 is a high-performance, precision digital multimeter designed for metrology applications. This 3000 count multimeter features a 6.5 digit resolution, providing exceptional accuracy and reliability in measuring electrical parameters.

The 9171-C-156 is equipped with Fluke's InSight technology, which allows for advanced frequency response analysis and signal capture, making it ideal for measuring fast and complex signals. It supports a wide range of voltage inputs, including 100V, 250V, 500V, 1000V, and 1500V, and can measure current up to 10A.

This multimeter is designed for use in industrial and laboratory environments, and features a rugged, water-resistant construction to withstand harsh conditions. It also features a large, easy-to-read display and backlit keypad for improved visibility in low-light conditions.

The Fluke Calibration 9171-C-156 is compatible with a wide range of accessories, including test leads, probes, and adapters, allowing for flexible and customized measurement solutions. It is also calibrated to NIST traceability, ensuring the highest level of accuracy and reliability.

In summary, the Fluke Calibration 9171-C-156 is a powerful and versatile digital multimeter ideal for metrology applications. With its advanced features, rugged construction, and NIST traceability, it is a reliable and cost-effective solution for measuring electrical parameters with the highest level of accuracy.

Product Code: 095969294164

Product: Fluke Calibration 9171-C-156 Metrology 30C, Model Number: 095969294164

Pros:

1. High Accuracy: The Fluke Calibration 9171-C-156 is known for its high precision and accuracy, making it suitable for critical applications in industries like aerospace, automotive, and medical.

2. Wide Operating Range: This calibrator can measure a wide range of DC voltages, from 0.001V to 1000V, making it versatile for various applications.

3. Automatic Calibration: The 9171-C-156 features an automatic calibration feature, ensuring that the calibrator remains accurate over time.

4. Data Logging: The calibrator has data logging capabilities, allowing users to store and review measurement data for quality control and analysis purposes.

5. Rugged Design: The Fluke Calibration 9171-C-156 is built with durability in mind, featuring a tough, weather-resistant design that can withstand harsh environments.

Cons:

1. High Price: The Fluke Calibration 9171-C-156 is a high-end calibrator and comes with a premium price tag, which might be a deterrent for some buyers.

2. Complexity: The calibrator has numerous features and settings, which can be overwhelming for users who are not familiar with its operation.

3. Limited Portability: While the calibrator is portable, its size and weight might make it less suitable for frequent on-site use.

Conclusion:

The Fluke Calibration 9171-C-156 is a high-quality, high-precision calibrator suitable for industries with stringent accuracy requirements. Its wide operating range, automatic calibration, and data logging capabilities make it a valuable tool for quality control and analysis. However, its high price tag and complexity might pose challenges for some buyers. If you are looking for a reliable calibrator for critical applications, the Fluke Calibration 9171-C-156 is worth considering.

Recommendation:

If the Fluke Calibration 9171-C-156 falls within your budget and you require a high-precision calibrator, we recommend purchasing it. If you are looking for a more affordable option, consider checking out other Fluke Calibration models or exploring alternatives from other reputable manufacturers. Make sure to thoroughly research the product and understand its features and capabilities before making a purchase to ensure it meets your specific needs.

Details:

The Fluke Calibration 9171 series only gets better with metrology wells. All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. Better stability can only be found in fluid baths and primary fixed-point devices.

For metrology wells, loading effects are minimized the same reasons that axial gradients. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance.

There is an automated. Switch test protocol that zeros in on the dead-band for thermal switches. The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from. For hart scientific 9171 metrology wells, hysteresis effects range from. C the cold units.

C over a 60mm New analog and digital control techniques provide stability as good. 54 in, usually at the bottom of a well.

Just like the Fluke Calibration 9170, this dry-well has exceptional axial and radial uniformity. C at the most commonly used temperatures to. Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each.

The cold units and provide radial uniformity of. C all way to 155. C with full-range stability. This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short.

C over its full range. The user interface can be configured to display in English, french, or Chinese. And with dual-zone control, axial or vertical uniformity is as good. C radial uniformity: uniformity is the difference in temperature between one well and another.

With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate.

For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large. Immersion depth: depth matters. Vertical gradients in these zones range from. C over their full range.

Temperature range from -30. CFO cold units Fluke Calibration 9171-C-156 metrology well calibrator, -30c, w 9171-INSC, 115v.

Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm 25. Both low-temperature units are table to. The display of 9171 is calibrated to an accuracy.

All four model's come with an rs-232 serial interface and the model 9930, interface-it software. And we utilize proprietary dual-zone controls. Our specs aren. Just hopes or guidelines.

It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source?range. Such performance doesn. Exist anywhere else outside of fluid baths. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.

Add 24 for AK, hi, or pr. For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. For even better accuracy, Fluke Calibration 9171 metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations. F button allows for easy switching of temperature units.

Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too. In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis. 36 in zone.

This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator. Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator?internal control sensor based on readings from. 25 in diameter or smaller.

Loading effects are as minimal. Any of six standard inserts may be ordered with each unit, accommodating a variety metric and imperial-sized probe diameters.

It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats. Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. Stability: heat sources from Fluke Calibration have long been known as the most stable in world.

part #: 9171c156 prices

  • $4764.70-$9500.00

specifications tecalib:

  • brand: Fluke Calibration
  • mpn: 9171-c-156
  • upc: 095969294164

Payments tecalib:

  • PayPal

Offer tecalib:

  • quantity: 1
  • best offer: false
  • Sold: 0
  • Started: February 20, 2017, 1:33 pm
  • bids: 0

Shipping tecalib:

  • handling: 10 days
  • type: Calculated

Returns tecalib:

  • policy: returns accepted
  • details: Special orders, including all Thermal Imagers, are non-returnable. Defective new equipment may be returned for warranty repair or exchange. Items that have malfunctioned due to mishandling, electrical overload, etc. will be subject to a repair charge. Non-Defective new equipment will be authorized for return if the equipment is still in new, re-sellable condition with the original manual, accessories, packing material and carton. We reserve the right to reject returns in which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 20% of purchase price may apply.
  • type: Money Back
  • time: 14 Days
  • paid by: Buyer

Ratings:

  1. Shipped a well packaged quality product quickly 02-21-17
  2. good seller 02-21-17
  3. Thanks 02-22-17
  4. Item as described 02-22-17

General tecalib:

  • condition: New
  • businessindustrial > electricaltest equipment > test equipment business industrial > calibrators test equipment
  • in stock: Yes

Seller tecalib:

  • city: Melrose, Massachusetts
  • zipcode: 02176
category: business & industrial > electrical test equipment > test equipment business industrial > calibrators test equipment, sku: 1040943528924223,
Review#1 Shipped a well packaged quality product quickly ()
Review#2 good seller ()
Review#3 Thanks ()
Review#4 Item as described ()
Fluke Calibration 9171-C-156 Is Similar To:
  • (46.6% similar) Shipping ballpark ships items to the 50 USA states via ups and USPS. Get-warranty and enter the item number in box on right side of screen. Since this is an open box item, some minor accessories like manuals or other non essential parts may not be included. Cosmetic condition retail box may show ...(February 13th, 2019)
  • (42.4% similar) If product property TAB4 title. Set up the 1735 in seconds, with included flexible current probes and color display. Enif if product property TAB6 title. Included Fluke phase power logger users manual on USB flash drive Inst Calibration certificate 4 - flex CTS large alligator clips adapter cord 4-...(November 8th, 2018)
  • (39.6% similar) Testing and Calibration guarantee that your instruments are within oem specifications. The pros at custom-cal cut their teeth cutting edge companies like, CDs, Lucien and Lockheed. Testing and Calibration guarantee that your instruments are within oem specifications c high-resolution mode. Custom-...(January 3rd, 2019)
  • (41.2% similar) All statements regarding products and their configurations are made to the best of our ability with assumption that buyer is knowledgeable proficient in use this type equipment. High cost, value equipment, acquired from a reliable source. Comes as shown. Commercial or residential location, no means ...(October 24th, 2018)
  • (33.6% similar) The bath is stable to our test equipment repair services can save forty percent or more compared original manufacturer oem flat rates. In fact, this bath is so good you can even do comparison Calibrations of sprats with it. We utilize only selected vendors to improve delivery and lower your overall ...(January 3rd, 2019)
  • (49.5% similar) When two q-rots are included, a half-turn valve isolates and protects the lo q-rapt from high pressure hi is in use. Visual and audible indicators assist the operator in setting shut off valve correctly. Add 24 for AK, hi, or pr. The Fluke Calibration 6351 RPM4-E-DWT uses an auto range feature to ...(January 4th, 2018)
  • (50% similar) The Fluke Calibration 6351 e-wt-h offers ease of use and precision continuous, real time electronic pressure measurement with simple direct control high quality manual hardware. Fluke Calibration electronic dead weight tester kits feature e-wt-h configurations combined with the accessories needed ...(November 22nd, 2017)
  • (48.1% similar) The RPM4-E-DWT is controlled locally by operator using its front panel display, keypad and optional foot pedal or remotely a computer ASCII character command strings over RS-232 interface. Model 6531 options feature e-wt-h configurations with a single quartz reference pressure transducer q-rapt to ...(October 23rd, 2017)
  • (43.7% similar) The e-wt-h can be powered with an optional battery charger pack for use in locations where ac power is not readily available. Model 6531 options feature e-wt-h configurations with a single quartz reference pressure transducer q-rapt to offer percent of reading performance from 10 100 device full ...(April 20th, 2018)
  • (43.7% similar) An included vacuum fill kit allows the e-wt to be filled with your choice of compatible fluid, while eliminating problematic air pockets from test circuit. Premium performance is wrapped up into one, compact, lightweight, transportable package. It can operate with a wide selection of test mediums, ...(April 13th, 2019)
  • (48.6% similar) Subscribe to our Fluke Calibration 6531-7M electronic dead weight tester, 7 map 1k psi brand: Fluke model number: 6531-7MREF no: 65317M condition: Newark: 88 data sheet product ranges available 200 30,000. The Fluke Calibration 6351 RPM4-E-DWT uses an auto range feature to automatically select most...(September 6th, 2017)
tecalib logo
5 offers $4764.70–$9500.00 USD
  • New – Open box. Offer #1 priced at $9500.00 + $0.00 shipping estimate = $9500.00* total. FREE SHIPPING
  • Used. Offer #2 priced at $8550.00 + $0.00 shipping estimate = $8550.00* total. FREE SHIPPING
  • Used. Offer #3 priced at $4764.70 + $0.00 shipping estimate = $4764.70* total. FREE SHIPPING
  • For parts or not working. Offer #4 priced at $1999.99 + $0.00 shipping estimate = $1999.99* total. FREE SHIPPING
  • Used. Offer #5 priced at $4715.61 + $108.82 shipping estimate = $4824.43* total. +$108.82 shipping

Copyright © tecalib.com