( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9171-F-156 ), ( UPC: 095969294287 )
The Fluke Calibration 9171-F-156 is a high-performance, precision voltage calibrator designed for metrology applications. This device is equipped with a wide voltage range of 150V DC, making it suitable for a variety of applications in the field of electrical measurement and calibration.
The 9171-F-156 features a 3.5-digit display with a resolution of 0.001V, ensuring accurate and reliable voltage readings. It is equipped with a built-in temperature compensation mechanism, which helps maintain its calibration stability even in fluctuating environmental temperatures.
This voltage calibrator is compliant with various international standards such as IEC 60065, IEC 61010, and ANSI/NCSL Z540.2, ensuring that it meets the highest standards of accuracy and reliability. It also includes a self-diagnostic function, which helps identify any potential issues and ensures the device is always operating at its peak performance.
The Fluke Calibration 9171-F-156 is designed with user-friendliness in mind. It features a simple and intuitive user interface, making it easy for users of all skill levels to operate. The device is also compact and lightweight, making it portable and easy to transport to different locations for on-site calibrations.
In summary, the Fluke Calibration 9171-F-156 is a powerful and reliable voltage calibrator that offers high precision, wide voltage range, and compliance with international standards. Its user-friendly design, self-diagnostic function, and portability make it an excellent choice for metrology applications in various industries. The product number 095969294287 can be used to locate and purchase this item.
Pros of Buying Fluke Calibration 9171-F-156:1. High Accuracy: The Fluke Calibration 9171-F-156 is known for its high accuracy, making it an excellent choice for metrology applications.
2. Wide Temperature Range: It can operate within a wide temperature range of -40 C to 85 C, making it suitable for various environmental conditions.
3. Robust Design: The device has a robust design, which ensures its durability and longevity, even under heavy usage.
4. Easy to Use: It comes with an intuitive user interface, making it easy to operate and use for both beginners and experts.
5. Compatibility: The device is compatible with various software and data management systems, making data analysis and reporting more convenient.
Cons of Buying Fluke Calibration 9171-F-156:1. High Price: The device is relatively expensive, which may not be within everyone's budget.
2. Limited Functionality: While it is a highly accurate and versatile device, it may not offer all the features of more advanced and expensive calibrators.
3. Maintenance: Like any electronic device, the Fluke Calibration 9171-F-156 requires regular maintenance to ensure its continued accuracy and reliability.
Conclusion:The Fluke Calibration 9171-F-156 is a high-quality and reliable device that offers excellent accuracy, durability, and ease of use. Its wide temperature range and compatibility with various software and data management systems make it a versatile choice for various metrology applications. While it is relatively expensive, its long-term benefits and accuracy justify its cost. Therefore, if you are looking for a high-quality calibrator for metrology applications, the Fluke Calibration 9171-F-156 is a recommended choice.
Vertical gradients in these zones range from. Temperature range from -30. CFO cold units Fluke Calibration 9171-F-156 metrology well calibrator, -30c, w 9171-INSF, 115v.
C all way to 155. C with full-range stability. 25 in diameter or smaller. C over their full range.
The display of 9171 is calibrated to an accuracy.
Loading effects are as minimal. C over its full range. 36 in zone.
The Fluke Calibration 9171 series only gets better with metrology wells. The user interface can be configured to display in English, french, or Chinese. Add 24 for AK, hi, or pr. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance.
It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source?range. Such performance doesn. Exist anywhere else outside of fluid baths. C in the cold units.
New analog and digital control techniques provide stability as good. Immersion depth: depth matters. 54 in, usually at the bottom of a well.
And we utilize proprietary dual-zone controls. The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from.
For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large. And with dual-zone control, axial or vertical uniformity is as good.
Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats.
For hart scientific 9171 metrology wells, hysteresis effects range from. There is an automated. Switch test protocol that zeros in on the dead-band for thermal switches. With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in. Stability: heat sources from Fluke Calibration have long been known as the most stable in world.
Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator?internal control sensor based on readings from. F button allows for easy switching of temperature units. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.
C over a 60mm In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis. For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6.
Any of six standard inserts may be ordered with each unit, accommodating a variety metric and imperial-sized probe diameters. C radial uniformity: uniformity is the difference in temperature between one well and another. Both low-temperature units are table to. For even better accuracy, Fluke Calibration 9171 metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations.
This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator. Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too. Just like the Fluke Calibration 9170, this dry-well has exceptional axial and radial uniformity.
This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each. It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats. For metrology wells, loading effects are minimized the same reasons that axial gradients.
C at the most commonly used temperatures to. Our specs aren. Just hopes or guidelines. All four model's come with an rs-232 serial interface and the model 9930, interface-it software.
Better stability can only be found in fluid baths and primary fixed-point devices. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate.