( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9172-D-R-156 ), ( UPC: 095969294461 )
The Fluke 9172-D-R-156 Calibration Kit is a meticulously designed tool for precision calibration tasks. This kit is specifically designed for the Fluke 425C Clamp Meter, and is compatible with 115V power supplies.
The kit includes the essential components needed for accurate and reliable calibration of your Fluke 425C Clamp Meter. The key component is the Fluke 9172-D Calibrator, which provides high precision and traceability to national standards. The calibrator is equipped with a USB interface for easy data transfer and management.
The kit also includes a set of high-quality calibration standards, including a 1000V DC voltage standard, a 10A DC current standard, and a 1000 resistance standard. These standards are designed to provide accurate and stable measurements, ensuring the highest level of precision in your calibration process.
The Fluke 9172-D-R-156 Calibration Kit is housed in a durable, portable case for easy transportation and storage. The case is designed to protect the calibrator and standards from damage during transport, ensuring they remain in top condition for use.
In summary, the Fluke 9172-D-R-156 Calibration Kit is an essential tool for anyone who relies on accurate and reliable measurements from their Fluke 425C Clamp Meter. Its high precision, compatibility with national standards, and durable design make it an indispensable addition to any toolkit.
Product: Fluke Calibration 9172-D-R-156 Metrology 425C Inspection Tool, 115V, Part Number 095969294461
Pros:1. High Accuracy: The Fluke Calibration 9172-D-R-156 is known for its high accuracy, making it ideal for precise measurements in various industrial applications.
2. Durable Construction: The tool is built to withstand harsh conditions, ensuring longevity and reliability in the field.
3. Wide Temperature Range: It operates in a wide temperature range, making it suitable for use in different environments.
4. Easy to Use: The user-friendly interface and intuitive design make it easy for operators of all skill levels to use effectively.
5. Compliance with Standards: The tool is compliant with various international standards, ensuring that your measurements meet the required specifications.
Cons:1. Cost: The Fluke Calibration 9172-D-R-156 is a high-end tool, which means it comes at a higher price point compared to other inspection tools.
2. Complexity: Despite its user-friendly design, the tool has a certain level of complexity due to its advanced features, which may require additional training or expertise to fully utilize.
3. Limited Portability: While portable, its size and weight may limit its ease of transportation compared to smaller, handheld tools.
Conclusion:The Fluke Calibration 9172-D-R-156 Metrology 425C Inspection Tool is a powerful and reliable tool for precise measurements in various industries. Its high accuracy, durability, and compliance with international standards make it a worthwhile investment for businesses that require precise measurements. However, its cost and complexity may be a deterrent for some, and its size and weight may limit its portability. Ultimately, the decision to purchase the 9172-D-R-156 depends on your specific needs, budget, and the requirements of your industry.
Recommendation:If you require accurate measurements in your industry and can afford the investment, the Fluke Calibration 9172-D-R-156 Metrology 425C Inspection Tool is a solid choice. Its durability and compliance with international standards ensure reliable and precise measurements, which can ultimately save your business time and money in the long run. However, if you are looking for a more budget-friendly or portable option, you may want to consider other inspection tools that offer similar features but at a lower price point or with a more compact design.
For metrology wells, loading effects are minimized the same reasons that axial gradients. Temperature range from 425. F Fluke Calibration 9172-D-R-156 metrology well calibrator, 425C,w 9172-insd,w ref, 115v. Such performance doesn. Exist anywhere else outside of fluid baths. And with dual-zone control, axial or vertical uniformity is as good.
The hot units and range from. Both low-temperature units are table to. C, depending on temperature.
For even better accuracy, Fluke Calibration 9172 metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations. C at the most commonly used temperatures to.
For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. With 203mm 8 in of immersion, the Fluke Calibration 9172 significantly reduces stem conduction errors at high temperatures. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large.
It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate. New analog and digital control techniques provide stability as good.
The hart scientific 9170 series metrology wells feature well depths of 203mm 8 in Fluke Calibration 9171, 9172, and. C over their full range. C over a 60mm. C radial uniformity: uniformity is the difference in temperature between one well and another.
Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator. ?internal control sensor based on readings from. Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too. With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in.
In addition to exceptional accuracy, the hart 9172 is stable from. All four model's come with an rs-232 serial interface and the model 9930, interface-it software. This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. The Fluke Calibration 9172 only gets better with metrology wells.
For hart scientific 9170 series metrology wells, hysteresis effects range from. In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis. The user interface can be configured to display in English, french, or Chinese. Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm 1.
Our specs aren. Just hopes or guidelines.
It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.
The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from. All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats.
F button allows for easy switching of temperature units. There is an automated. Switch test protocol that zeros in on the. Dead-band for thermal switches. Vertical gradients in these zones range from.
Add 24 for AK, hi, or pr. 25 in diameter or smaller. Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats.
And we utilize proprietary dual-zone controls. Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each.
C in the cold units. The Fluke Calibration 9172 metrology well calibrators provides temperatures from 35. C with a calibrated display accurate. Better stability can only be found in fluid baths and primary fixed-point devices. This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator.
Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance.
Immersion depth: depth matters. Any of six standard inserts may be ordered with each unit, accommodating a variety metric and imperial-sized probe diameters. Stability: heat sources from Fluke Calibration have long been known as the most stable in world.