( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9173-B-156 ), ( UPC: 095969294607 )
The Fluke Calibration 9173-INSB is a high-performance, precision voltage standard designed for applications in metrology, calibration, and electrical testing. This calibrator, with the model number 9173-156, operates on a 115V power supply and is identified by the unique SKU number 095969294607.
The Fluke 9173-INSB is an excellent choice for operators seeking a reliable, accurate, and versatile voltage standard. This calibrator features an impressive 0.0005% accuracy and a 0.001V resolution, making it suitable for a wide range of calibration and testing applications.
The calibrator's robust design includes a high-quality, color touchscreen display, allowing for easy and intuitive operation. It also features a built-in USB interface, enabling data transfer and remote control capabilities.
The 9173-INSB is equipped with a comprehensive suite of measurement functions, including DC voltage, AC voltage, and resistance, ensuring that it can meet the requirements of various applications. Its advanced features, such as auto-zero, auto-ranging, and integrated power supply, contribute to its ease of use and versatility.
In summary, the Fluke Calibration 9173-INSB is a powerful and versatile voltage standard, ideally suited for metrology, calibration, and electrical testing applications. Its outstanding accuracy, high resolution, and extensive measurement functions, combined with its user-friendly design, make it an excellent investment for any professional seeking a reliable and precise voltage standard.
Product: Fluke Calibration 9173-INSB Metrology 700C
Pros:1. High Precision: The Fluke Calibration 9173-INSB Metrology 700C is known for its high precision, making it an ideal choice for calibration and measurement applications in various industries.
2. Wide Temperature Range: It operates within a wide temperature range, which is beneficial for use in environments with varying temperatures.
3. Durable Construction: The product is built to withstand harsh conditions, ensuring long-term use and reliability.
4. Easy to Use: It features an intuitive interface, making it user-friendly even for those not familiar with complex calibration tools.
Cons:1. High Price: The Fluke Calibration 9173-INSB Metrology 700C is quite expensive compared to other calibration tools, which might be a deterrent for some buyers.
2. Requires Frequent Calibration: Like all calibration tools, it requires regular recalibration to maintain accuracy, which can add to the total cost of ownership.
3. Heavy and Bulky: Its size and weight might make it less portable than smaller calibration tools, which could be a disadvantage in certain applications.
Conclusion:The Fluke Calibration 9173-INSB Metrology 700C is a high-quality, precision calibration tool designed for use in various industries. Its durable construction, wide temperature range, and user-friendly interface are its main strengths. However, its high price and the requirement for frequent recalibration are potential drawbacks. If the benefits of this calibration tool outweigh its costs for your specific application, then it could be an excellent investment. If not, consider looking into less expensive alternatives with comparable precision.
Even the 700. C unit model achieves stability of. The Fluke Calibration 9173 has a display accuracy of. C radial uniformity: uniformity is the difference in temperature between one well and another.
25 in diameter or smaller. All four model's come with an rs-232 serial interface and the model 9930, interface-it software. C at the most commonly used temperatures to.
Loading effects are as minimal. C in the cold units. C over a 60mm 2.
Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. The hot units and range from. It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats.
Both low-temperature units are table to. ?still nothing better for a quick test of industrial temperature sensor performance. The hart 9170 series is 160mm. The hart scientific 9170 series metrology wells feature well depths of 203mm 8 in Fluke Calibration 9171, 9172, and this has limited value because unique characteristics reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator.
All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. F button allows for easy switching of temperature units. The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from.
Temperature range from 50. Cc Fluke Calibration 9173-B-156 metrology well calibrator, 700c, w 9173-insb, 115v. For hart scientific 9170 series metrology wells, hysteresis effects range from. Better stability can only be found in fluid baths and primary fixed-point devices. 54 in, usually at the bottom of a well.
Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance. Of course, there. Dry block calibrators. It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source.
For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large. For work between 50. C, the Fluke Calibration 9173 provides unmatched performance. For even better accuracy, Fluke Calibration 9170 series metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations.
Any of six standard inserts may be ordered with each unit, accommodating a variety metric and imperial-sized probe diameters. C and an immersion depth of 203mm 8 in. Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each. 3 in deep to facilitate temperature of -45.
Vertical gradients in these zones range from. Our specs aren. Just hopes or guidelines. Such performance doesn. Exist anywhere else outside of fluid baths. For metrology wells, loading effects are minimized the same reasons that axial gradients.
With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate.
Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too.
Immersion depth: depth matters. This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. In fact, Fluke Calibration makes and will continue to make some of the best performing, portable, fast dry-wells world. Stability: heat sources from Fluke Calibration have long been known as the most stable in world.
And with dual-zone control, axial or vertical uniformity is as good.
New analog and digital control techniques provide stability as good.
The Fluke Calibration 9171 series only gets better with metrology wells. In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis. The user interface can be configured to display in English, french, or Chinese. There is an automated. Switch test protocol that zeros in on the. Dead-band for thermal switches.
Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm Stability and uniformity performance of this unit are enough to dramatically reduce uncertainty budgets for Calibrations thermometers at high temperatures. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.
Add 24 for AK, hi, or pr. Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator. ?internal control sensor based on readings from. C over their full range.
Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats.