( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9173-DW-156 ), ( UPC: 095969413664 )
The Fluke Calibration Metrology 700C is a high-performance digital multimeter designed for precise and reliable measurement in calibration and metrology applications. This specific model, the 9173-dw-156, is a 115V version of the 700C series.
The Fluke 700C features a wide measurement range of DC 1000V to AC/DC 1000V, with a maximum input of 10A. It offers a high input impedance of 10 M , which helps to prevent loading effects on the DUT (Device Under Test). The meter also boasts a high resolution of 0.0001% of reading, ensuring accurate and precise measurements.
The Fluke 700C is built with a rugged and ergonomic design, making it suitable for use in various environments. It features a large, backlit display with a high contrast for easy readability even in low light conditions. The meter also has a built-in rechargeable battery that provides up to 24 hours of continuous use, ensuring long operation time between charges.
The 700C supports a wide range of measurement functions, including DC voltage, AC voltage, DC current, resistance, frequency, and temperature. It also comes with a built-in relay output for remote control and data logging capabilities. The meter is compatible with FlukeConnect, a wireless data management system that allows users to connect the meter to a computer or mobile device for data transfer and analysis.
The Fluke 700C is calibrated and traceable to national standards, ensuring the highest level of accuracy and reliability. It is also equipped with a safety feature that disables the measurement function if the test leads are disconnected, preventing accidental exposure to high voltage.
In summary, the Fluke Calibration Metrology 700C 9173-dw-156 is a high-performance digital multimeter designed for precise and reliable measurement in calibration and metrology applications. Its wide measurement range, high resolution, and built-in safety features make it an ideal choice for users who require accurate and reliable measurements in their work.
Pros of Buying Fluke Calibration Metrology 700C (9173-dw-156):1. High Accuracy: This device is known for its high accuracy and precision, making it ideal for calibration and metrology applications.
2. Wide Range: It can measure a wide range of electrical parameters, including DC voltage, AC voltage, DC current, and resistance.
3. Durable: Fluke products are known for their durability and reliability, making this device suitable for use in harsh environments.
4. User-Friendly: The device has a user-friendly interface, making it easy to use even for those who are not familiar with metrology equipment.
5. Compatibility: It is compatible with various software and data logging tools, allowing for easy data analysis and reporting.
Cons of Buying Fluke Calibration Metrology 700C (9173-dw-156):1. High Cost: The device is quite expensive, which may be a deterrent for some buyers.
2. Complexity: While the interface is user-friendly, the device itself can be quite complex and may require training to use effectively.
3. Limited Portability: While it is portable, the device is larger and heavier than some other options, which may make it less suitable for field use.
Conclusion:The Fluke Calibration Metrology 700C (9173-dw-156) is a high-quality, accurate, and reliable device suitable for calibration and metrology applications. While its high cost and limited portability may be a deterrent for some buyers, its durability, wide range of capabilities, and user-friendly interface make it a strong contender for those in need of a high-performance metrology tool.
Recommendation:If you are in need of a high-performance metrology tool for calibration and metrology applications, the Fluke Calibration Metrology 700C (9173-dw-156) is a strong contender. Its high accuracy, wide range of capabilities, and user-friendly interface make it a valuable asset for any laboratory or industrial setting. However, be aware of its high cost and limited portability before making a decision.
All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. The hart 9170 series is 160mm 6.
Immersion depth: depth matters. 54 in, usually at the bottom of a well. Any of six standard inserts may be ordered with each unit, accommodating a variety metric and imperial-sized probe diameters.
C at the most commonly used temperatures to. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.
For hart scientific 9170 series metrology wells, hysteresis effects range from. C and an immersion depth of 203mm 8 in. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance.
C in the cold units. Temperature range from 50. Cc Fluke Calibration 9173-DW-156 metrology well calibrator, 700c, no insert, 115v. Stability: heat sources from Fluke Calibration have long been known as the most stable in world. And with dual-zone control, axial or vertical uniformity is as good.
F button allows for easy switching of temperature units. 25 in diameter or smaller. Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator?internal control sensor based on readings from.
It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source?range. For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6.
Both low-temperature units are table to. 3 in deep to facilitate temperature of -45. This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator. With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in.
For work between 50. C, the Fluke Calibration 9173 provides unmatched performance. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate. C radial uniformity: uniformity is the difference in temperature between one well and another.
The Fluke Calibration 9171 series only gets better with metrology wells. For even better accuracy, Fluke Calibration 9170 series metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations. And we utilize proprietary dual-zone controls. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large.
Better stability can only be found in fluid baths and primary fixed-point devices. Even the 700. C unit model achieves stability of.
Dry block calibrators. Such performance doesn. Exist anywhere else outside of fluid baths. Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats.
The user interface can be configured to display in English, french, or Chinese. Add 24 for AK, hi, or pr.
The hot units and range from. Loading effects are as minimal. There is an automated. Switch test protocol that zeros in on the dead-band for thermal switches.
The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from. Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too. All four model's come with an rs-232 serial interface and the model 9930, interface-it software.
There?still nothing better for a quick test of industrial temperature sensor performance. Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. Our specs aren. Just hopes or guidelines. This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short.
New analog and digital control techniques provide stability as good. In fact, Fluke Calibration makes and will continue to make some of the best performing, portable, fast dry-wells world. C over their full range.
It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats. For metrology wells, loading effects are minimized the same reasons that axial gradients. Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each.
Stability and uniformity performance of this unit are enough to dramatically reduce uncertainty budgets for Calibrations thermometers at high temperatures. Vertical gradients in these zones range from.
Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm The Fluke Calibration 9173 has a display accuracy of.
In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis.