( Brand: Fluke ), ( Manufacturer Part Number: 719PRO ), ( Part Type: Pressure ), ( UPC: 095969673815 )
The 719pro 095969673815 Calibrator, model Fluke 300, is a high-precision electric pressure calibrator designed for professionals in various industries such as manufacturing, energy, HVAC, and more. This 300-gram device is equipped with advanced features that ensure accurate and reliable pressure measurements, making it an essential tool in quality control and safety applications.
The Fluke 300 calibrator boasts a digital display with a high resolution of 0.1% of full scale, providing clear and easy-to-read measurements. It is capable of measuring pressure up to 6000 PSI (41,370 kPa) with a repeatability of 0.02% of full scale, ensuring consistent and reliable results. The calibrator is also equipped with an automatic zero function, which helps to eliminate any system errors and ensures the most accurate measurements.
The Fluke 300 calibrator is designed with ease of use in mind. It features a compact and lightweight design, making it easy to carry and transport between different locations. The device is also equipped with a built-in pressure relief valve, which protects the calibrator from overpressure and helps to prevent damage.
The calibrator is powered by a rechargeable lithium-ion battery, which provides up to 10 hours of continuous use on a single charge. It also comes with a USB cable for easy charging and data transfer. The device is compatible with a range of computer software, including FlukeConnect, which allows for remote monitoring and data logging.
The Fluke 300 calibrator is built to last, with a rugged and durable design that can withstand harsh environments. It is also certified to meet the highest industry standards, including ISO 9001, ISO 17025, and CE. This ensures that the device delivers accurate and reliable measurements, while also providing peace of mind to users who require compliance with regulatory requirements.
In summary, the 719pro 095969673815 Calibrator, model Fluke 300, is a high-precision electric pressure calibrator that offers accurate and reliable measurement capabilities, ease of use, and durability. Its advanced features and compliance with industry standards make it an excellent choice for professionals in various industries who require accurate pressure measurements.
Pros of buying Fluke 300 Calibrator (719PRO 095969673815):1. High Accuracy: The Fluke 300 Calibrator is known for its high accuracy, ensuring reliable and precise readings.
2. Versatility: It supports a wide range of pressure types, including absolute, gauge, and differential, making it a versatile tool for various applications.
3. Durable Construction: The calibrator is built with a robust and durable design, ensuring long-lasting use in various environments.
4. User-friendly Interface: The intuitive and easy-to-use interface allows users of all levels of expertise to operate the calibrator effectively.
5. Calibration Capabilities: The Fluke 300 Calibrator can be used to calibrate a wide range of pressure measurement devices, saving you time and money.
Cons of buying Fluke 300 Calibrator (719PRO 095969673815):1. High Cost: The Fluke 300 Calibrator is a premium product with a higher price tag compared to some other calibrators on the market.
2. Limited Portability: Due to its size and weight, the calibrator may not be as portable as smaller handheld devices, making it less suitable for on-the-go use.
3. Complexity: While the user interface is user-friendly, the calibrator's advanced features can be complex and may require additional training or expertise to fully utilize.
Conclusion:The Fluke 300 Calibrator (719PRO 095969673815) is an excellent choice for professionals who require high precision and versatility in their pressure measurement and calibration processes. While its high cost and limited portability may be drawbacks for some users, its accuracy, durability, and calibration capabilities make it a valuable investment for those who prioritize reliability and precision.
Recommendation:If you are looking for a high-quality, reliable, and accurate pressure calibrator for your professional applications, the Fluke 300 Calibrator (719PRO 095969673815) is an excellent choice. Consider its cost and portability in relation to your specific needs, but overall, its benefits outweigh its cons, making it a worthwhile investment for many professionals.
This function will only work on the lower screen. Measure pressure with external modules the product has a digital interface to be used with external pressure modules. Net equipment. Vacuum should not be applied to any gauge pressure sensor.
Make sure the vent on the pump is open. Temperature measurement with ETD probe pressure switch test connect a pressure switch to the product pressure switch connection to do a pressure switch test change the setup to setup 4 default switch test listed under setups in the more configuration menu choices.
Bleed the pump slowly until the pressure switch closes. Push to zero the pressure sensor when vented to atmospheric pressure. Make sure to choose the sensor based on working pressures and accuracy. Use low volume tubing when possible.
If a custom probe is used, enter the r0 and coefficients with the serial interface. If ol is shown on any pressure display, the pressure should be reduced or vented immediately to prevent product damage or possible personnel injury. 7 pressure vernier adjust knob 8 pressure source or measurement connector 9 input terminals to measure current, volts and contact closure for switch test. These buttons correspond to messages on the display.
In the source mode, the product supplies ma to 24 ma with its own internal 24 volt supply, whereas in the simulate mode the product acts as a two wire transmitter and an external 24 volt supply is necessary. Note the display shows ol when the measured current is more than the nominal range of current measurement 24 ma. Note to ensure accuracy of the product, the product must be zeroed before a device is calibrated. Connect the probe to the product and configure the display to read temperature.
When this is done carefully, the pressure bleed rate can be carefully controlled and this helps when taking down scale pressure readings. Warning to prevent personal injury pressure sensors can be damaged and or personnel injury can occur due to improper application of pressure. To fully decrease or bleed off the pressure, slowly turn the vent knob to the open position. High altitude use about 3000 ft or 1000 meters, or use at cold temperatures, can limit the pump to about 90 of its rated pressure.
voltage measurement measure temperature with an ETD to measure temperature with an ETD probe, select the ETD function on one of the displays. If a normally closed switch, the top of the display shows close. Make sure that the pressure vacuum knob is set for the correct function for pressure and Nash for vacuum. Speak with an agent today.
Runs the electric pump. 2 three function buttons. For example if the current measured is shown as 75 then the ma value is 16 ma.
See the zero function use section. Since the interface between the product and the module is digital, all accuracy and display resolution is derived from the module. Turns on and off the product.
Media compatibility the product has a unique user accessible valve cleaning port for easy pump service. 4 arrow buttons. Close the vent after the product is zeroed. In addition, qualifying electric test product orders are shipped free.
And sets pump and error limits 5 pump button. About equipment. These modules are available in different ranges and types that include gauge, vacuum, differential, and absolute. In these situations, start the calibration with the vernier in the full counter clockwise position and then, when the electric pump reaches its limit, turn the vernier clockwise.
The necessary quick fit hose connectors and bps adapter for non not applications are also included. Pump connection electric pump considerations the product uses a small, battery powered pneumatic pump that can quickly build rated high pressure. Apply pressure with the pump slowly until the switch opens.
Get the ultimate in measurement flexibility with the large backbit screen, which displays three parameters at once pressure measurement from internal or external sensor sourced simulated or measured ma values temperature measured by optional ETD probe product features 1 power button. 6 home button. Connect the modules to the interface and select ext external sensor.
Push the pump key and see the pressure or vacuum increase until the necessary pressure is reached.
If necessary, review the calibrator interface section to select the correct configuration. To source current, the same connections are used. The product can measure a maximum of 30 v dc.
Close the vent knob. The function keys can also be used to step the output in either 25 steps 4, 8, 12, 16, 20 ma or ma and ma. See the clean the valve assembly section for how to clean these valves. Make sure to only expose the product to clean, dry gases.
Ol is shown when the pressure exceeds of the nominal range of the sensor or when a vacuum in excess of 2 psi is applied on gauge range sensors. Fluke recommends that this type of hose be used to get the best performance from the product. Connect the product to the switch with the pressure switch terminals to the pressure switch contacts DE energized dry contacts. From the configuration screen, select ma source or ma sim 2w.
The display shows ol when the measured temperature is outside the nominal measurement range of the ETD function below c or above c. Note the display shows ol when the measured voltage is more than the nominal range of the voltage measurement 30 v. Note in switch test mode the display update rate is increased to help capture pressure input changes. Connect the pump from the product to the input of the pressure switch.
The product has one internal sensor and many optional external sensors EPS are available. The 719PRO includes a full functioning loop calibrator that sources, simulates and measures ma signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges.
The standard probe has a 10 inch insertion depth with a inch diameter stainless steel sheath. Measure pressure to measure pressure, connect the product with the correct fitting.
The range on the product is set to at 4 ma and at 20 ma. Push any of the arrow soft keys to start the output mode and use the arrow soft keys to adjust the ma output. Make sure the correct probe type is selected. Select a pressure setting for the display that is used.
Note the pump motor speed will start slowly when pressure is low use the fine adjustment vernier to fine tune the pressure vacuum indication as necessary. The polarity of the terminals does not matter. Used to configure the product. When the switch is open, open is shown on the display.
This will raise the pressure to set the necessary reading. Net provides electrical testing equipment and products for a wide range of electrical applications. When the fittings are installed and the product is connected to the unit under test UT, the product is ready. The product display shows ol when an inappropriate pressure is applied.
Note the factory default type is pt100 385 so if the product is used with the Fluke 720 ETD probe pn , it is not necessary to set the probe type. See the set the ETD probe type section. Refer to table 9 for information on over pressure and burst pressure ratings.
3 zero button. Even with this enhanced sample rate, pressurization of the device under test should be done slowly to ensure accurate readings. Controls ma source sim. Current is measured in ma and percentage of range.
Zero the product if necessary. Zeros pressure measurements. Select the volts function on one of the displays.