( Brand: Fluke Calibration ), ( Manufacturer Part Number: P3011INHGP ), ( Part Type: Tester Pump )
The Fluke Calibration P3011-INHG Vacuum Deadweight Tester is a highly accurate and reliable instrument designed for measuring vacuum pressure. This particular model, P3011INHG, is specifically calibrated for 30 inches of Hg (inches of mercury) vacuum pressure.
The P3011-INHG Vacuum Deadweight Tester features a robust and durable design, making it suitable for various industrial applications. The tester is equipped with a 30-inch mercury manometer, which provides high precision and stability in measuring vacuum pressure. The manometer is mounted on a sturdy base, ensuring stability during use.
The tester also includes a 30-inch INHG pump, which allows for easy and efficient evacuation of the manometer. This pump is designed to operate quietly, minimizing noise and disturbance in the working environment. The P3011-INHG Vacuum Deadweight Tester is also equipped with a built-in air bleeder, which allows for quick and easy air release, ensuring accurate pressure readings.
The P3011-INHG Vacuum Deadweight Tester is calibrated to meet the highest standards of accuracy, ensuring that it delivers consistent and reliable results. The tester is also equipped with a calibration certificate, which provides traceability to national standards.
The P3011-INHG Vacuum Deadweight Tester is easy to use, with clear and easy-to-read pressure indicators. The tester also includes a built-in pressure release valve, which allows for safe and easy pressure release when the measurement is complete.
In summary, the Fluke Calibration P3011-INHG Vacuum Deadweight Tester is a high-quality and reliable instrument for measuring vacuum pressure. Its robust design, accurate calibration, and easy-to-use features make it an excellent choice for various industrial applications.
Pros of buying a Fluke Calibration P3011-INHG Vac Deadweight Tester:1. High Accuracy: The Fluke P3011-INHG is a high-precision instrument, providing accurate and reliable measurements of vacuum pressure up to 30 inches of Hg.
2. Durable: Fluke products are known for their durability and robustness, making the P3011-INHG a reliable choice for industrial applications.
3. Easy to Use: The device features a simple and intuitive interface, making it easy for users of all experience levels to operate.
4. Calibration Certified: The P3011-INHG is factory calibrated and traceable to NIST, ensuring the highest level of accuracy.
5. Versatile: The device can be used for various applications such as quality control, research, and development, and in various industries like aerospace, semiconductor, and pharmaceuticals.
Cons of buying a Fluke Calibration P3011-INHG Vac Deadweight Tester:1. High Cost: The Fluke P3011-INHG is a high-end vacuum pressure gauge and its price reflects its superior quality and features.
2. Bulkiness: The device is quite large and heavy, which might be inconvenient for users who require portability.
3. Limited Range: The P3011-INHG only measures vacuum pressure up to 30 inches of Hg, which may not be sufficient for applications requiring a wider range of measurements.
4. Requires Manual Calibration: While the device is factory calibrated, it may require periodic recalibration, which can be a time-consuming and costly process.
Recommendation:The Fluke Calibration P3011-INHG Vac Deadweight Tester is a high-quality and reliable instrument for measuring vacuum pressure. Its accuracy, durability, and ease of use make it a suitable choice for various industrial applications. However, its high cost and bulkiness are factors to consider before making a purchase. If the need for a high-precision instrument and the ability to perform accurate measurements outweighs the cons, the Fluke P3011-INHG is an excellent choice. If budget or portability are primary concerns, there are less expensive and more portable options available in the market.
They are manufactured from materials that provide stability, durability, and low thermal coefficients distortion. 5 map capacity in one unit.
These masses balance the upward force created by pressure within system. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated masses force are loaded on area, which rises freely within its. Operating principle: Fluke Calibration p3011 deadweight testers are the primary standard for pressure measurements.
The use of press cal allows for an improved accuracy. The masses are stored in a high-quality case with self-locking mechanism to protect them during transit of reading. Our experience and knowledge of piston cylinder production Calibration ensure the precision performance required for today. ?demanding requirements.
The Fluke Calibration p3000 series is culmination of over 50 years experience in production and design primary pressure standards. Add 24 for AK, hi, or pr.
Ten percent above the maximum pressure is required. Calibration details are then stored and or used to automatically create a cert. With features designed to improve accuracy and performance, increase reliability simplify operation these deadweight testers can be used calibrate virtually any pressure sensing device, including transducer-Er's, transmitters, gauges or switches. Piston cylinder assemblies: the assembly is heart of each deadweight tester.
Each instrument can be calibrated to local gravity at no extra cost. Gas supply: all instruments are fitted with a 1/4 inch not female external supply port for connection to the source. The masses for vacuum ranges and optional. Ne increment are stainless steel or aluminum.
5, 1 8, 4, 3 and 2 not bps female adaptors, operating fluid where applicable spare seals. Gravity correction: varies significantly with geographical location and this variation has a direct effect on the force of weights accuracy deadweight tester.
Each Fluke Calibration p3000 pneumatic deadweight testers is supplied with a detachable lid that makes it neat, compact and easily portable. Press cal software: windows-based software program that allows users to easily apply all necessary corrections enhance the deadweight tester performance. Subscribe to our Fluke Calibration P3011-INHG-P vacuum deadweight tester, 30 inhg with pump brand: Fluke model number: P3011-INHG-Pref no: P3011INHGP condition: Newark: 81 data sheet product ranges from through psi 140 bar accuracy better than.
The hand pump option is not available on instruments above 500 psi 3.
For vacuum requirements, an external pump can be connected to the 1/4 inch port instrument base: there are four basic variations in pneumatic offering single pressure, vacuum, dual and oil-lubricated pneumatically driven high-pressure model's. All units are provided with an accredited Calibration certificate, m14x1.
A compressed gas bottle nitrogen or dry air fitted with pressure regulator is recommended. Increased accuracy option of. Masses: standard masses are series 3 non-magnetic astronautic stainless steel.