( Brand: Fluke Calibration ), ( Manufacturer Part Number: P3012-MBAR-P ), ( Part Type: Tester Pump ), ( UPC: 095969637428 )
The Fluke Calibration P3012-MBAR is a highly precise and reliable gas deadweight tester designed for calibrating pressure instruments in various industries. This model, with the item number 095969637428, is equipped with a 1000 mbar pump, making it suitable for applications requiring high pressure measurement accuracy.
The P3012-MBAR features a sturdy and durable construction, ensuring long-term reliability and resilience in harsh working environments. The tester's pressure range is from 0 to 1000 mbar, with a maximum pressure of 1025 mbar, providing a wide scope for measuring pressure variations accurately.
The tester's 1000 mbar pump delivers consistent and precise pressure, ensuring reliable readings even in demanding applications. The P3012-MBAR also includes a built-in pressure relief valve to prevent overpressure and protect the equipment from damage.
The tester's high-quality design ensures easy and convenient operation, with intuitive controls and a large, easy-to-read digital display. It also features an integrated battery charger and an auto-shutoff feature to conserve battery life.
The Fluke Calibration P3012-MBAR is calibrated and certified to meet the highest industry standards, ensuring you can trust its measurements for critical applications. It is also designed to meet the requirements of international standards, such as ISO and ASTM, providing peace of mind for users worldwide.
In conclusion, the Fluke Calibration P3012-MBAR is a high-performance and reliable gas deadweight tester, ideal for calibrating pressure instruments in various industries. With its durable construction, precise pump, and user-friendly design, it offers unparalleled accuracy and reliability, making it an essential tool for any calibration laboratory or industrial application.
Pros of buying a Fluke Calibration P3012-MBAR Gas Deadweight Tester:1. High Accuracy: The Fluke P3012-MBAR is known for its high accuracy, with a maximum uncertainty of 0.01% of full scale, making it suitable for precise pressure measurement applications.
2. Durable Construction: The tester features a rugged and sturdy construction, making it resistant to harsh environments, ensuring long-term use.
3. Easy to Use: The P3012-MBAR comes with a user-friendly interface and software, allowing users of varying expertise levels to operate it effectively.
4. Versatile: The tester can be used for various industries, including calibration, manufacturing, and research. It is also compatible with various calibration standards.
5. 1000 mbar pump: The tester includes a 1000 mbar pump, which allows for quick and easy pressure changes in the test chamber.
Cons of buying a Fluke Calibration P3012-MBAR Gas Deadweight Tester:1. High Cost: The Fluke P3012-MBAR is a high-end product, and its price might be prohibitive for some users with a limited budget.
2. Requires Calibration: Like any other pressure measurement device, the Fluke P3012-MBAR requires regular calibration to maintain its accuracy.
3. Large Size: The tester is relatively large, which might be a limitation for users who require portability.
4. Complexity: Although the P3012-MBAR is user-friendly, its functionality can be complex, which might require some training for users unfamiliar with the device.
Recommendation:The Fluke Calibration P3012-MBAR Gas Deadweight Tester is an excellent choice for users in need of high-precision pressure measurement, especially in industries requiring strict accuracy standards. Despite its high cost and size, its durability, ease of use, and versatility make it a valuable investment for users with the necessary budget. Therefore, we recommend the Fluke P3012-MBAR to users who prioritize precision and reliability in their pressure measurement applications.
Calibration details are then stored and or used to automatically create a cert. Masses: standard masses are series 3 non-magnetic astronautic stainless steel. Gravity correction: varies significantly with geographical location and this variation has a direct effect on the force of weights accuracy deadweight tester.
Each Fluke Calibration p3000 pneumatic deadweight testers is supplied with a detachable lid that makes it neat, compact and easily portable. Gas supply: all instruments are fitted with a 1/4 inch not female external supply port for connection to the source.
Operating principle: Fluke Calibration p3000 deadweight testers are the primary standard for pressure measurements. 5 map capacity in one unit. Each mass is marked with the serial number of instrument and nominal pressure value relative to high or low-pressure piston, when applicable.
Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated masses force are loaded on area, which rises freely within its.
Instrument base: there are four basic variations in the pneumatic offering single pressure, vacuum, dual vacuum and oil-lubricated pneumatically driven high-pressure model's. They are manufactured from materials that provide stability, durability, and low thermal coefficients distortion cm s2. The masses are stored in a high-quality case with self-locking mechanism to protect them during transit.
Add 24 for AK, hi, or pr. All units are provided with an accredited Calibration certificate, m14x1.
Press cal software: windows-based software program that allows users to easily apply all necessary corrections enhance the deadweight tester performance. Subscribe to our Fluke Calibration P3012-MBAR-P gas deadweight tester, 1000 mbar, with pump brand: Fluke model number: P3012-MBAR-Pref no: p3012mbarp condition: Newark: 28 data sheet product ranges from vacuum through psi 140 bar accuracy better than.
Increased accuracy option of. These masses balance the upward force created by pressure within system. The hand pump option is not available on instruments above 500 psi A compressed gas bottle nitrogen or dry air fitted with pressure regulator is recommended operated optional hand pumps dual vacuum model's available psi, bar, kg cm2, KP and map ranges available piston cylinder design provides stability repeatability built-in pneumatic pumps for vacuum piston flotation indicator high quality needle valves provide optimum control mounted spirit level adjustable fattest station o-rings eliminates the need PDF tape wrenches improved case spring loaded latches hood sturdy weight box hinged lid side handles easy transport Fluke Calibration P3012-MBAR-P deadweight tester, 1000 mbar, pump.
The use of press cal allows for an improved accuracy. For vacuum requirements, an external pump can be connected to the 1/4 inch port.
5, 1 8, 4, 3 and 2 not bps female adaptors, operating fluid where applicable spare seals. Ten percent above the maximum pressure is required. The masses for vacuum ranges and optional. Ne increment are stainless steel or aluminum. Each instrument can be calibrated to local gravity at no extra cost.
Piston cylinder assemblies: the assembly is heart of each deadweight tester.