( Brand: Fluke Calibration ), ( Manufacturer Part Number: P3014-KPA-P ), ( Part Type: Tester Pump ), ( UPC: 095969637503 )
The Fluke Calibration P3014-KPA Gas Deadweight Tester is a high-performance instrument designed for precise pressure measurement in various industrial and research applications. This tester, specifically model P3014-KPA, is capable of measuring up to 1000 kPa (10 bar) of pressure, making it ideal for use with gases such as nitrogen, oxygen, and hydrogen.
The P3014-KPA features a robust and durable design, with a sturdy aluminum housing that ensures long-term reliability and resistance to corrosion. The instrument is equipped with a high-precision piston and a linear variable differential transformer (LVDT) pressure sensor, which provides accurate and stable pressure readings within a range of 0.025% of full scale.
The P3014-KPA comes with a built-in digital display that offers clear and easy-to-read measurements, as well as a variety of communication options, including RS-232, USB, and Ethernet. The instrument also includes a pump for easily and quickly filling the tester chamber, ensuring fast and efficient pressure testing.
Furthermore, the P3014-KPA is designed to meet the highest standards of accuracy and consistency, with a temperature compensation feature that ensures stable and accurate measurements even in changing environmental conditions. The tester is also calibrated to traceability standards, providing confidence in its measurement capabilities.
Overall, the Fluke Calibration P3014-KPA Gas Deadweight Tester is a powerful and reliable tool for pressure measurement applications, offering precision, accuracy, and durability in a compact and easy-to-use package.
Part number: 095969637503
Pros of buying a Fluke Calibration P3014-KPA Gas Deadweight Tester:1. High Accuracy: The Fluke P3014-KPA offers a high level of accuracy, ensuring that your measurements are reliable and trustworthy. This is crucial in industries where precise measurements are essential.
2. Wide Range: With a capacity of up to 1000 kPa, this tester can handle a wide range of applications, making it versatile and suitable for various industries.
3. Durable and Reliable: Fluke products are known for their durability and reliability, and the P3014-KPA is no exception. It is built to withstand harsh environments and frequent use, ensuring long-term performance.
4. Easy to Use: The P3014-KPA features a user-friendly interface, making it easy to operate, even for those who are not familiar with gas pressure testers.
5. Calibration Certificate: Fluke provides a calibration certificate with the tester, which can be essential for compliance with industry regulations and standards.
Cons of buying a Fluke Calibration P3014-KPA Gas Deadweight Tester:1. High Price: The Fluke P3014-KPA is a premium product, and its price reflects its high-quality construction and features. This might be a disadvantage for those with a limited budget.
2. Requires Regular Calibration: Like all pressure testers, the Fluke P3014-KPA requires regular calibration to maintain its accuracy. This can add to the overall cost of ownership.
3. Bulky and Heavy: Due to its robust construction and high capacity, the Fluke P3014-KPA is a relatively large and heavy device. This might make it less portable than some other pressure testers on the market.
Recommendation:If you require a high-accuracy, high-capacity gas pressure tester for industrial applications and are willing to invest in a premium product, the Fluke Calibration P3014-KPA Gas Deadweight Tester is an excellent choice. Its durability, ease of use, and calibration certificate make it a reliable and trustworthy tool for your measurements. However, if budget is a concern, you might want to consider less expensive alternatives that may not offer the same level of accuracy or capacity.
Subscribe to our Fluke Calibration P3014-KPA-P gas deadweight tester, 1000 kpa, with pump brand: Fluke model number: P3014-KPA-Pref no: p3014kpap condition: Newark: 03 data sheet product ranges from vacuum through psi 140 bar accuracy better than. Instrument base: there are four basic variations in the pneumatic offering single pressure, vacuum, dual vacuum and oil-lubricated pneumatically driven high-pressure model's.
These masses balance the upward force created by pressure within system.
Operating principle: Fluke Calibration p3000 deadweight testers are the primary standard for pressure measurements. Increased accuracy option of masses: standard masses are series 3 non-magnetic astronautic stainless steel gas operated with optional hand pumps dual vacuum pressure model's available psi, bar, kg cm2, kpa and map ranges available piston cylinder design provides stability repeatability built-in pneumatic pumps for vacuum piston flotation indicator high quality needle valves provide optimum control mounted spirit level adjustable fattest station o-rings eliminates the need PDF tape or wrenches improved case spring loaded latches hood sturdy weight box hinged lid side handles easy transport Fluke Calibration P3014-KPA-P deadweight tester, 1000 kpa, pump. Add 24 for AK, hi, or pr.
Each Fluke Calibration p3000 pneumatic deadweight testers is supplied with a detachable lid that makes it neat, compact and easily portable. 5, 1 8, 4, 3 and 2 not bps female adaptors, operating fluid where applicable spare seals. Calibration details are then stored and or used to automatically create a cert.
The masses for vacuum ranges and optional. Ne increment are stainless steel or aluminum. For vacuum requirements, an external pump can be connected to the 1/4 inch port. Piston cylinder assemblies: the assembly is heart of each deadweight tester.
Each mass is marked with the serial number of instrument and nominal pressure value relative to high or low-pressure piston, when applicable. Gravity correction: varies significantly with geographical location and this variation has a direct effect on the force of weights accuracy deadweight tester.
Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated masses force are loaded on area, which rises freely within its. A compressed gas bottle nitrogen or dry air fitted with pressure regulator is recommended. Fluke Calibration p3000 series vacuum and dual pressure model's the combined are extremely versatile instruments providing through 500 psi 3.
The use of press cal allows for an improved accuracy. Gas supply: all instruments are fitted with a 1/4 inch not female external supply port for connection to the source. All units are provided with an accredited Calibration certificate, m14x1.
They are manufactured from materials that provide stability, durability, and low thermal coefficients distortion. 5 map capacity in one unit. The masses are stored in a high-quality case with self-locking mechanism to protect them during transit.
Press cal software: windows-based software program that allows users to easily apply all necessary corrections enhance the deadweight tester performance. Each instrument can be calibrated to local gravity at no extra cost. The hand pump option is not available on instruments above 500 psi 3.
Ten percent above the maximum pressure is required.