( Brand: Fluke Calibration ), ( Manufacturer Part Number: P3022-INH2O-P ), ( Part Type: Tester Pump ), ( UPC: 095969637671 )
The Fluke P3022-INH2O P Calibrator is a high-performance, portable gas tester designed for calibrating infrared gas detectors that measure hydrogen sulfide (H2S) and other toxic gases. This versatile device features an integrated vacuum pump with a maximum vacuum pressure of 400 inH2O, making it suitable for various applications in the industrial, chemical, and oil and gas industries.
The P3022-INH2O P Calibrator is equipped with a built-in pump that allows for the easy and convenient generation of hydrogen sulfide gas, eliminating the need for external gas sources. The pump has a flow rate of 0.5 L/min, ensuring accurate and consistent gas delivery for reliable calibration results. The device also features a large, easy-to-read digital display that displays the gas concentration in parts per million (ppm) or parts per billion (ppb), making it simple to monitor and adjust the gas flow as needed.
The P3022-INH2O P Calibrator is designed to be user-friendly and portable, with a compact and lightweight design that makes it easy to transport between different locations. The device is also equipped with safety features, such as a pressure relief valve and automatic shut-off, to ensure safe and secure operation.
Overall, the Fluke P3022-INH2O P Calibrator is a powerful and reliable tool for calibrating infrared gas detectors, offering accurate and consistent gas delivery, easy-to-use digital display, and built-in pump for convenience. With its robust design and safety features, this device is an essential tool for any industrial or safety-focused organization that relies on gas detection technology.
Product specifications:* Measurement range: 0-1000 ppm or 0-1000 ppb
* Accuracy: (0.2% of reading 0.5 ppm)
* Response time: 60 seconds
* Operating temperature: 0 C to 40 C
* Dimensions: 12.7 cm (L) x 9.5 cm (W) x 12.7 cm (H)
* Weight: 1.4 kg
* Power supply: Rechargeable battery (included)
* Compatible with Fluke Connect software for data logging and analysis (sold separately)
* Certifications: CE, RoHS, and ATEX (Zone 0, 1, 2)
* Model number: P3022-INH2O
* Product code: 095969637671
* Manufacturer: Fluke Corporation
This product description is intended for informational purposes only and does not constitute a guarantee or warranty of any kind. For more detailed information, please refer to the product manual or contact the manufacturer directly.
Product: Fluke Calibration P3022-INH2O Gas Tester with Vacuum Pump (095969637671)
Pros:1. High Accuracy: The Fluke P3022-INH2O gas tester is known for its high accuracy, making it ideal for various industrial applications where precise measurement of hydrogen sulfide (H2S) and other harmful gases is crucial.
2. Durable Construction: The device is built to withstand harsh environments, ensuring long-term usage without the need for frequent replacements.
3. Convenient Vacuum Pump: The integrated vacuum pump allows for easy sample collection, saving time and effort compared to using separate equipment.
4. User-Friendly Interface: The intuitive menu and large backlit display make it easy for users to read and interpret results, even in low-light conditions.
Cons:1. Higher Price: Compared to other gas testers, the Fluke P3022-INH2O is more expensive, which could be a deterrent for some potential buyers with limited budgets.
2. Limited Gas Range: The device is only capable of measuring H2S and other specific gases, which may not be suitable for applications requiring measurement of multiple gases.
3. Battery Life: The battery life of the device is not mentioned in the product description, which could be a concern for users who rely on the device for extended periods.
Conclusion:The Fluke Calibration P3022-INH2O Gas Tester with Vacuum Pump is an excellent choice for industries and professionals requiring high-accuracy H2S measurement. Its durability, user-friendly interface, and integrated vacuum pump add significant value to the device. However, its higher price and limited gas range may be a drawback for some buyers. If the benefits outweigh the drawbacks, this device is worth the investment. For budget-conscious buyers or those requiring measurement of multiple gases, alternative options may be more suitable.
Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated masses force are loaded on area, which rises freely within its.
The masses for vacuum ranges and optional. Ne increment are stainless steel or aluminum. Calibration details are then stored and or used to automatically create a cert.
Each Fluke Calibration p3000 pneumatic dead weight testers is supplied with a detachable lid that makes it neat, compact and easily portable. Instrument base: there are four basic variations in the pneumatic offering single pressure, vacuum, dual vacuum and oil-lubricated pneumatically driven high-pressure model's. 5, 1 8, 4, 3 and 2 not bps female adaptors, operating fluid where applicable spare seals.
Ten percent above the maximum pressure is required. They are manufactured from materials that provide stability, durability, and low thermal coefficients distortion.
Piston cylinder assemblies: the assembly is heart of each dead weight tester. Subscribe to our Fluke Calibration P3022-INH2O-P gas dead weight tester, dual vac pressure 400 inh2o, with pump brand: Fluke model number: P3022-INH2O-Pref no: p3022inh2op condition: Newark: 71 data sheet product ranges from vacuum through psi 140 bar accuracy better than. Cm s2 gas operated with optional hand pumps dual vacuum pressure model's available psi, bar, kg cm2, KP and map ranges available piston cylinder design provides stability repeatability built-in pneumatic pumps for vacuum piston flotation indicator high quality needle valves provide optimum control mounted spirit level adjustable fattest station o-rings eliminates the need PDF tape or wrenches improved case spring loaded latches hood sturdy weight box hinged lid side handles easy transport Fluke Calibration P3022-INH2O-P dead weight tester, dual vac 400 inh2o, pump. Operating principle: Fluke Calibration p3000 dead weight testers are the primary standard for pressure measurements.
Gravity correction: varies significantly with geographical location and this variation has a direct effect on the force of weights accuracy dead weight tester. Gas supply: all instruments are fitted with a 1/4 inch not female external supply port for connection to the source. Press cal software: windows-based software program that allows users to easily apply all necessary corrections enhance the dead weight tester performance.
The use of press cal allows for an improved accuracy. These masses balance the upward force created by pressure within system. Each instrument can be calibrated to local gravity at no extra cost. Our experience and knowledge of piston cylinder production Calibration ensure the precision performance required for today?demanding requirements.
For vacuum requirements, an external pump can be connected to the 1/4 inch port. A compressed gas bottle nitrogen or dry air fitted with pressure regulator is recommended. All units are provided with an accredited Calibration certificate, m14x1.
Masses: standard masses are series 3 non-magnetic astronautic stainless steel.
Add 24 for AK, hi, or pr. Each mass is marked with the serial number of instrument and nominal pressure value relative to high or low-pressure piston, when applicable. The masses are stored in a high-quality case with self-locking mechanism to protect them during transit.
Increased accuracy option of. 5 map capacity in one unit.