( Brand: Fluke Calibration ), ( Manufacturer Part Number: P3114-MPA ), ( Part Type: Oil Tester ), ( UPC: 095969638135 )
The Fluke P3114-MPA Calibration Oil Deadweight Tester is a high-precision instrument designed for calibrating hydraulic pressure gauges and transducers. This tester is specifically engineered to operate at an impressive pressure capacity of 70 Megapascals (MPa), making it suitable for a wide range of industrial applications.
The tester features a robust, all-steel construction, ensuring durability and reliability in demanding environments. Its precision-machined cylinder and piston provide accurate readings, while the large, easy-to-read dial facilitates quick and accurate pressure measurements. The tester also includes a built-in bleed valve for efficient and safe pressure release.
The Fluke P3114-MPA Calibration Oil Deadweight Tester is equipped with a high-quality, leak-free connection system, ensuring a secure and reliable connection to your hydraulic pressure gauge or transducer. The tester is designed for use with Fluke's calibration oil, which is specifically formulated to provide consistent and reliable results.
The tester comes with a comprehensive calibration certificate, providing you with the peace of mind that comes from knowing your hydraulic pressure gauges and transducers are accurately calibrated. The Fluke P3114-MPA Calibration Oil Deadweight Tester is a must-have tool for any industrial maintenance or calibration professional.
The product number for the Fluke P3114-MPA Calibration Oil Deadweight Tester is 095969638135. This tester is backed by Fluke's reputation for quality and reliability, and it is sure to become an essential part of your calibration toolkit.
Pros of buying a Fluke Calibration P3114-MPA Deadweight Tester:1. High accuracy: This tester is designed to provide precise and accurate readings within its intended range of 0 to 70 MPa, making it suitable for calibration purposes.
2. Durable construction: The Fluke P3114-MPA is built to withstand harsh environments, ensuring longevity and reliability.
3. Easy to use: The tester features an intuitive interface and is simple to operate, reducing the risk of user error.
4. Wide range of compatible pressure transducers: This tester is compatible with a variety of pressure transducers, making it a versatile tool for various applications.
Cons of buying a Fluke Calibration P3114-MPA Deadweight Tester:1. High cost: Compared to other pressure testers, the Fluke P3114-MPA is quite expensive, which may not be feasible for individuals or small businesses with a limited budget.
2. Requires calibration: Despite its high accuracy, the tester needs to be calibrated periodically to ensure its continued accuracy, which can be time-consuming and expensive.
3. Limited portability: Although the tester is lightweight and portable, it may not be suitable for fieldwork due to its size and the need for a flat and stable surface for operation.
Conclusion:The Fluke Calibration P3114-MPA Deadweight Tester is a high-quality and reliable tool for calibration purposes. Its high accuracy, durable construction, and compatibility with various pressure transducers make it an excellent choice for professional use. However, its high cost and limited portability may be drawbacks for some users. If the benefits of its high precision and reliability outweigh the costs and inconveniences, then this tester is an excellent investment. But for those with a limited budget or who require a more portable solution, other options may be more suitable.
With features designed to improve accuracy and performance, increase reliability simplify operation these deadweight testers can be used calibrate virtually any pressure sensing device, including transducers, transmitters, gauges or switches. These weights balance the upward force created by pres-sure within system. They are manufactured from materials that provide stability, durability, and low thermal coed. Cents distortion. The Fluke Calibration p3100 instrument is supplied with a detachable lid which makes it neat, compact and easily portable.
The pressure is measured when placed on a correctly spinning and floating piston. Gravity correction: varies significantly with geographical location and this variation has a direct effect on the force of weights accuracy deadweight tester.
Instrument base: there are three basic variations in the hydraulic offering single low pressure, high pressure and dual piston model's. All Fluke Calibration p3100 units are provided with a traceable certificate of accuracy, weight mass details, 1/8 inch, 4/3 inch and 2 not or bps female adaptors, operating fluid where applicable spare seals.
Subscribe to our Fluke Calibration P3114-MPA oil deadweight tester, 70 mpa brand: Fluke model number: P3114-MPA ref no: P3114mpa condition: Newark: 35 data sheet product ranges 20,000 psi 1,400 bar accuracy better than weight masses: standard masses are series 3 non-magnetic astronautic stainless steel. Units can be supplied in psi, bar, kg cm2, and mpa. Operating principle: deadweight testers are the primary standard for pressure measurement.
Each mass is marked with the serial number of instr-meant and nominal pressure value relative to high or low-pressure piston, when applicable. The weight masses are stored in a high-quality case with self locking mechanism to protect them during transit.
Our experience and knowledge of piston cylinder production Calibration ensure the precision performance required for today?demanding requirements. Piston cylinder assemblies: the assembly is heart of each deadweight tester.
Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses force are loaded on area, which rises freely within its.
The total pressure measured is summation of weights plus piston weight carrier assembly. Each instrument can be calibrated to local gravity at no extra cost mineral oil and distilled water model's dual piston model's allow Calibration over a wide range psi, bar, kg cm2, KP mpa ranges available dual for pressure range built-in lever hand pump now standard on all hydraulic model's mounted spirit level adjustable fee thigh quality screw press fine control test station design with o-rings eliminates the need PDF tape or wrenches acrylic reservoir provides visibility of fluid quality improved case spring-loaded latches hood built-in drain plug remove old fluid sturdy weight box hinged lid side Han-dales easy transport Fluke P3114-MPA deadweight tester, 70. Add 24 for AK, hi, or pr. Units feature a built-in priming pump for large volume applications, piston flotation indicators and high quality screw press fine pressure control.
Optional fractional weights are stainless steel and or solution heat treated aluminum. The Fluke Calibration p3100 series is culmination of over 50 years experience in production and design high performance pressure standards. The Fluke Calibration p3100 model's are available in single or dual piston formats for increased operating ranges. The Fluke Calibration p3100 are robust instruments highly accurate, quick and easy to use.