( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9170-C-156 ), ( UPC: 095969293921 )
The Fluke Calibration 9170-INSC is a high-performance, standalone digital multimeter designed for precise and reliable electrical measurements. This specific model, 9170-INSC 156, is a part of Fluke's Metrology 45C series, which is renowned for its accuracy and robustness.
The 9170-INSC is a 6.5-digit true RMS multimeter that offers a wide range of measurement capabilities, including DC and AC voltage, current, resistance, and frequency. It features a large, backlit LCD display that provides clear and easy-to-read measurements, even in low-light conditions. The multimeter also includes an auto-ranging function that automatically selects the appropriate measurement range, ensuring accurate results.
One of the standout features of the 9170-INSC is its high accuracy, with a voltage measurement uncertainty of 0.005% 2 LSB (least significant bit) and a current measurement uncertainty of 0.005% 0.05 LSB. This level of precision makes it ideal for use in calibration and metrology applications, where precise measurements are essential.
The multimeter is powered by 115V AC and includes a safety-rated, detachable lead set with fused test leads. It also features a rugged, water-resistant housing that is designed to withstand harsh industrial environments. The 9170-INSC also includes a number of protective features, including an overvoltage protection circuit and a drop protection system, ensuring that it can withstand accidental drops and other mishaps.
The Fluke Calibration 9170-INSC is a powerful and accurate digital multimeter that is designed for use in a wide range of industrial and metrology applications. Its high precision, rugged construction, and wide range of measurement capabilities make it an ideal choice for professionals who require the highest level of accuracy in their electrical measurements.
Product Details:* Model Number: 9170-INSC 156
* Manufacturer: Fluke Calibration
* Series: Metrology 45C
* Voltage Range: 1000V AC/DC
* Current Range: 20A AC/DC
* Resistance Range: 0.001 to 20M
* Frequency Range: 1Hz to 10MHz
* Display: 6.5-digit, backlit LCD
* Accuracy: 0.005% 2 LSB (voltage), 0.005% 0.05 LSB (current)
* Power: 115V AC
* Leads: Safety-rated, detachable lead set with fused test leads
* Protection: Overvoltage protection, drop protection
* Housing: Rugged, water-resistant
* Dimensions: 8.19 x 5.09 x 2.99 inches (208 x 129.3 x 76.0 mm)
* Weight: 2.9 lbs (1.3 kg)
* Part Number: 095969293921
* Warranty: 3 years
This product has a model number of 9170-INSC 156 and the part number is 095969293921. It is a 6.5-digit true RMS multimeter with a wide range of measurement capabilities, including DC and AC voltage, current, resistance, and frequency. It features a large, backlit LCD display, auto-ranging function, and high accuracy. The multimeter is powered by 115V AC and includes a safety-rated, detachable lead set with fused test leads. It also features a rugged, water-resistant housing and protective features, including overvoltage protection and drop protection. The product dimensions are 8.19 x 5.09 x 2.99 inches and it weighs 2.9 lbs. It has a 3-year warranty.
Product: Fluke Calibration 9170-INSC Metrology 45C
Pros:1. High Accuracy: The Fluke Calibration 9170-INSC is known for its high accuracy, making it suitable for precise measurements in various industries.
2. Versatility: It can measure temperature in a wide range, from -200 C to 1300 C, making it a versatile tool for various applications.
3. Rugged Design: The device is designed to withstand harsh environments, ensuring its longevity and reliability in the field.
4. Easy to Use: The user-friendly interface and intuitive controls make it easy for users to operate, even without prior calibration experience.
5. Compliance: It meets the requirements of various international standards, ensuring its reliability and credibility.
Cons:1. High Cost: The Fluke Calibration 9170-INSC is a high-end device and comes with a premium price tag.
2. Complexity: While the device is user-friendly, it may still require some technical knowledge to fully understand and utilize all its features.
3. Limited Portability: Due to its size and weight, it might not be the best choice for frequent on-the-go measurements.
Conclusion:The Fluke Calibration 9170-INSC Metrology 45C is an excellent choice for industries that require high precision temperature measurements. Its rugged design, versatility, and high accuracy make it a reliable tool. However, the high cost and limited portability might be a deterrent for some users. If the benefits of the device outweigh the drawbacks, it is a worthwhile investment.
Recommendation:If you are in an industry that requires high-precision temperature measurements and can afford the premium price tag, the Fluke Calibration 9170-INSC Metrology 45C is a recommended choice. Its high accuracy, versatility, and reliability make it a valuable addition to any toolkit. However, for less demanding applications or for those on a tight budget, there may be more affordable alternatives available that still meet your needs.
Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator?internal control sensor based on readings from. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.
The hart 9170 series is 160mm 6. For even better accuracy, Fluke Calibration 9170 series metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations.
The Fluke Calibration 9170 series only gets better with metrology wells. With axial uniformity of. For hart scientific 9170 series metrology wells, hysteresis effects range from 0.
With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in.
54 in, usually at the bottom of a well.
Immersion depth: depth matters. 3 in of immersion depth. Stability: heat sources from Fluke Calibration have long been known as the most stable in world. Vertical gradients in these zones range from.
F button allows for easy switching of temperature units. Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats. C radial uniformity: uniformity is the difference in temperature between one well and another.
And with dual-zone control, axial or vertical uniformity is as good. The user interface can be configured to display in English, french, or Chinese.
This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator. And we utilize proprietary dual-zone controls. The Fluke Calibration 9170 achieves lowest temperatures of series, reaching -45. C in normal room conditions.
3 in deep to facilitate temperature of -45. All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world.
It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large. C and radial uniformity of. It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source?range.
Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm 25 in diameter or smaller. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate. Our specs aren. Just hopes or guidelines.
The cold units and provide radial uniformity of. This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. Both low-temperature units are table to.
Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too. For metrology wells, loading effects are minimized the same reasons that axial gradients. There is an automated. Switch test protocol that zeros in on the dead-band for thermal switches. Add 24 for AK, hi, or pr.
For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. C over its full temperature range up to 140. C and has 160mm 6. All four model's come with an rs-232 serial interface and the model 9930, interface-it software. Such performance doesn. Exist anywhere else outside of fluid baths.
C, the Fluke Calibration 9170 delivers exceptional uncertainty budgets and is perfect for a variety of pharmaceutical other applications. In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis. Temperature range from -45. CFO cold units Fluke Calibration 9170-C-156 metrology well calibrator, -45c, w 9170-insc, 115v.
Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each. C in the cold units. C over their full range.
The Fluke hart 9170 is stable to. Loading effects are as minimal.
New analog and digital control techniques provide stability as good. C at the most commonly used temperatures to. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance.
C over a 60mm 2.