
( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9170-D-156 ), ( UPC: 095969293969 )
The Fluke Calibration 9170-INSd is a high-performance digital multimeter designed for metrology applications. This device, with model number 9170-INSd 156, operates on 115V and is identified by the SKU 095969293969.
The 9170-INSd is a versatile tool, equipped with a 6.2-inch (156mm) high-resolution color LCD display, providing clear and precise readings. Its large, backlit display is ideal for use in various lighting conditions, ensuring accurate readings in any environment.
This Fluke Calibration multimeter is designed for precision measurements, featuring an input impedance of 10 M , which minimizes loading effects and ensures accurate readings. It also comes with a wide range of measurement functions, including DC voltage, AC voltage, DC current, resistance, and diode/continuity tests.
The 9170-INSd is built to withstand the rigors of industrial use, featuring a rugged, ergonomic design for easy handling and a water-resistant construction to protect against splashes and moisture. It also features a self-calibration function, ensuring that it maintains its accuracy over time.
In addition, the 9170-INSd is equipped with advanced safety features, such as overvoltage protection and a Category III safety rating, making it safe to use in high-voltage environments. It also includes a data hold function, which allows users to store and recall readings for future reference.
In conclusion, the Fluke Calibration 9170-INSd 156 is a powerful and reliable digital multimeter, ideal for metrology applications. With its large display, wide range of measurement functions, rugged construction, and advanced safety features, this device is a valuable tool for any professional who requires precise and reliable measurements.
The Fluke Calibration 9170-INSD is a high-performance digital multimeter (DMM) designed for metrology applications. Here are some pros and cons of buying this particular model:
Pros:1. High Accuracy: The 9170-INSD is designed to meet the requirements of calibration labs and metrology applications, offering high accuracy and reliability.
2. Wide Range: It covers a wide range of measurements, from DC to AC voltage and current, resistance, capacitance, and frequency, making it a versatile tool for various applications.
3. Rugged Construction: The device is built to withstand harsh environments, featuring a compact and rugged design with an IP67 rating for water and dust protection.
4. Advanced Features: The 9170-INSD offers advanced features such as auto-ranging, data logging, and remote operation through a USB or Wi-Fi connection.
Cons:1. Price: The Fluke Calibration 9170-INSD is a premium product, and its high price may be a significant drawback for some buyers.
2. Complexity: The device's advanced features and capabilities may be overwhelming for users who require a simpler and more straightforward tool.
3. Compatibility Issues: Some users may encounter compatibility issues with older software or hardware, as the 9170-INSD requires a newer version of Fluke's software to fully utilize its features.
Conclusion:The Fluke Calibration 9170-INSD is an excellent choice for metrology applications that require high accuracy and versatility. Its rugged construction, advanced features, and wide range of measurements make it an indispensable tool for calibration labs and other high-precision environments. However, its high price and potential complexity may make it an unsuitable option for users with simpler needs and smaller budgets.
Recommendation:If you are in a metrology or calibration lab, or if you require a high-precision DMM for your applications, the Fluke Calibration 9170-INSD is an excellent investment. Its advanced features and high accuracy will help you achieve the best results, even in challenging environments. However, if you have a limited budget or require a simpler tool, you may want to consider other options that offer a more balanced combination of performance and affordability.
All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats.
And we utilize proprietary dual-zone controls. Immersion depth: depth matters. The Fluke Calibration 9170 achieves lowest temperatures of series, reaching -45. C in normal room conditions. Stability: heat sources from Fluke Calibration have long been known as the most stable in world.
C, the Fluke Calibration 9170 delivers exceptional uncertainty budgets and is perfect for a variety of pharmaceutical other applications. The cold units and provide radial uniformity of. Temperature range from -45. CFO cold units Fluke Calibration 9170-D-156 metrology well calibrator, -45c, w 9170-insd, 115v. Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator?internal control sensor based on readings from.
The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from. In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis.
There is an automated. Switch test protocol that zeros in on the dead-band for thermal switches. Both low-temperature units are table to. For hart scientific 9170 series metrology wells, hysteresis effects range from 0.
C over its full temperature range up to 140. C and has 160mm in zone. With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in. For even better accuracy, Fluke Calibration 9170 series metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations.
The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate. Our specs aren. Just hopes or guidelines. Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm.
The Fluke hart 9170 is stable to. And with dual-zone control, axial or vertical uniformity is as good. Such performance doesn. Exist anywhere else outside of fluid baths.
Vertical gradients in these zones range from. New analog and digital control techniques provide stability as good. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance.
Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats. 3 in of immersion depth. This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator.
For metrology wells, loading effects are minimized the same reasons that axial gradients. The Fluke Calibration 9170 series only gets better with metrology wells.
C at the most commonly used temperatures to. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.3 in deep to facilitate temperature of -45.
C over their full range. Add 24 for AK, hi, or pr.
The user interface can be configured to display in English, french, or Chinese. F button allows for easy switching of temperature units. 54 in, usually at the bottom of a well.
C and radial uniformity of. Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. With axial uniformity of.
C in the cold units. Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each. Loading effects are as minimal.
For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source?range. C over a 60mm in diameter or smaller. C radial uniformity: uniformity is the difference in temperature between one well and another.
This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. The hart 9170 series is 160mm 6.
All four model's come with an rs-232 serial interface and the model 9930, interface-it software. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large. Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too.