( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9171-D-156 ), ( UPC: 095969294201 )
The Fluke Calibration 9171-D-156 is a high-precision voltage standard designed for metrology applications. This device is part of Fluke's renowned 9171 series, which is known for its accuracy and reliability.
The 9171-156 features a wide input voltage range of 0 to 115V, making it suitable for a variety of applications. It is equipped with a built-in 30C temperature sensor, allowing for temperature compensation, ensuring consistent and accurate readings in varying environmental conditions.
The 9171-D-156 is designed with a high-resolution, 4 1/2-digit, 20-digit internal display for precise measurement. It also includes a built-in self-calibration feature, ensuring that the device remains accurate over time. The device is compliant with various international standards, including IEC 60945, IEC 61010-1, and IEC 61010-2-010, ensuring its safety and reliability.
The Fluke Calibration 9171-D-156 is housed in a rugged, aluminum enclosure, providing protection against harsh industrial environments. It includes a number of connectivity options, including GPIB, USB, and RS-232, allowing for easy integration with other devices and systems.
In summary, the Fluke Calibration 9171-D-156 is a versatile and reliable voltage standard, suitable for metrology applications. Its wide input voltage range, built-in temperature sensor, and self-calibration feature ensure accurate and consistent readings in varying conditions. Its rugged construction and connectivity options make it a versatile tool in a variety of industrial environments.
Product: Fluke Calibration 9171-D-156 Metrology 30C, Model Number: 095969294201
Pros:1. High Accuracy: This Fluke calibrator offers high accuracy, with a relative accuracy of 0.002% of reading or 0.05 LSB, ensuring reliable and precise measurements.
2. Wide Temperature Range: It operates in a wide temperature range of -40 C to 85 C, making it suitable for various environmental conditions.
3. Versatile Measurement Capabilities: The Fluke 9171-D-156 supports voltage, resistance, current, and frequency measurements, making it a versatile tool for various applications.
4. User-Friendly Interface: Its intuitive interface and large, backlit display make it easy to use, even in low-light conditions.
5. Rugged Design: The device is designed to withstand harsh environments, featuring a shock-resistant case and water-resistant connectors.
Cons:1. High Price: The Fluke Calibration 9171-D-156 is a premium product, and its high price might be a barrier for some users.
2. Limited Frequency Range: While it supports standard frequencies, its limited frequency range might not meet the needs of users requiring measurements beyond the supported range.
3. Requires Calibration: Like all measurement devices, the Fluke 9171-D-156 requires regular calibration to maintain its accuracy, which may incur additional costs over time.
Conclusion:The Fluke Calibration 9171-D-156 is a high-performance, versatile, and reliable calibrator that offers excellent accuracy and supports a wide temperature range. Its user-friendly interface and rugged design make it a valuable tool for various applications. However, its high price and limited frequency range are potential drawbacks that users should consider before making a purchase. If you require a device with a more extensive frequency range or have a limited budget, you may want to explore alternative options.
Recommendation:If you are in need of a high-accuracy calibrator and have the budget for it, the Fluke Calibration 9171-D-156 is an excellent choice. Its robust design, extensive measurement capabilities, and user-friendly interface make it a worthy investment for professionals in various industries like electronics, aerospace, and automotive. However, if you have a different budget or require a device with a more extensive frequency range, consider researching alternative products to find the best fit for your specific needs.
Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each. For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6.
C over their full range. 25 in diameter or smaller. 54 in, usually at the bottom of a well.
The cold units and provide radial uniformity of. Add 24 for AK, hi, or pr. It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source?range. In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis.
F button allows for easy switching of temperature units. Better stability can only be found in fluid baths and primary fixed-point devices. Stability: heat sources from Fluke Calibration have long been known as the most stable in world.
Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats.
The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from. Such performance doesn. Exist anywhere else outside of fluid baths.
C radial uniformity: uniformity is the difference in temperature between one well and another. Any of six standard inserts may be ordered with each unit, accommodating a variety metric and imperial-sized probe diameters.
For even better accuracy, Fluke Calibration 9171 metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations. For hart scientific 9171 metrology wells, hysteresis effects range from 0.
C all way to 155. C with full-range stability. And with dual-zone control, axial or vertical uniformity is as good. All four model's come with an rs-232 serial interface and the model 9930, interface-it software. Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world.
Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too. It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats.
C over its full range. C in the cold units. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate.
For metrology wells, loading effects are minimized the same reasons that axial gradients. Temperature range from -30. CFO cold units Fluke Calibration 9171-D-156 metrology well calibrator, -30c, w 9171-INSD, 115v.
For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large. Just like the Fluke Calibration 9170, this dry-well has exceptional axial and radial uniformity. The user interface can be configured to display in English, french, or Chinese. Immersion depth: depth matters.
C at the most commonly used temperatures to. There is an automated. Switch test protocol that zeros in on the dead-band for thermal switches. This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator.
Our specs aren. Just hopes or guidelines. New analog and digital control techniques provide stability as good. With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in.
Loading effects are as minimal. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source. And we utilize proprietary dual-zone controls. C over a 60mm 2.
Both low-temperature units are table to. All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. The Fluke Calibration 9171 series only gets better with metrology wells.
Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance.
Vertical gradients in these zones range from. 36 in zone.