( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9172-B-R-156 ), ( UPC: 095969294386 )
The Fluke 9172-B-R-156 is a high-precision calibration tool designed for metrology applications. This specific model, part number 095969294386, is a part of Fluke's 425C Insulation Resistance Megohm Meter series.
The Fluke 9172-B-R-156 is an advanced calibration standard, offering exceptional accuracy and reliability. It is designed to provide calibration traceability to national standards, making it an ideal tool for industries that require strict adherence to quality and safety protocols.
The device features a wide range of measurement capabilities, including insulation resistance, capacitance, and low voltage DC resistance. It is equipped with a high-resolution display that provides clear and precise readings, and also includes an advanced data logging feature that allows users to store and analyze measurement data.
The Fluke 9172-B-R-156 is compatible with 115V power supply and is designed for easy operation, with a user-friendly interface and intuitive menus. It also comes with a carrying case for easy transportation and storage.
Overall, the Fluke 9172-B-R-156 is a powerful and versatile calibration tool that is ideal for metrology applications where accuracy and reliability are critical. Its advanced features, wide measurement range, and easy-to-use interface make it a valuable asset for any laboratory or industrial setting.
Product: Fluke Calibration 9172-B-R-156 Metrology 425C Inspection Battery Operated, 115V, 095969294386
Pros:1. High Accuracy: The Fluke Calibration 9172-B-R-156 is known for its high accuracy, making it an ideal choice for calibration and inspection tasks.
2. Battery Operated: Being battery operated, it offers portability and flexibility, allowing you to use it anywhere without needing a power source.
3. Wide Voltage Range: It operates on a wide voltage range of 115V, making it suitable for various applications.
4. Durable: Fluke products are known for their durability and reliability, ensuring long-term use.
5. Trusted Brand: Fluke is a well-respected brand in the field of calibration and measurement tools, ensuring you're getting a high-quality product.
Cons:1. Cost: The Fluke Calibration 9172-B-R-156 is a premium product, and its cost may be a deterrent for some buyers.
2. Requires Calibration: Like all measurement tools, this one also requires regular calibration to maintain its accuracy.
3. Limited Uses: While it's a versatile tool, it may not be suitable for tasks requiring specific features not offered by this model.
Conclusion:The Fluke Calibration 9172-B-R-156 is a high-quality, accurate, and reliable calibration and inspection tool. Its battery operation and wide voltage range make it a versatile choice. However, its premium price may be a limiting factor for some buyers. If you value accuracy and reliability in a portable and flexible tool, and are willing to invest in a quality product, the Fluke Calibration 9172-B-R-156 is an excellent choice. If budget is a concern, you may want to consider other options that offer similar features at a lower price point.
In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis. Stability: heat sources from Fluke Calibration have long been known as the most stable in world. For even better accuracy, Fluke Calibration 9172 metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations.
Both low-temperature units are table to. F button allows for easy switching of temperature units.
internal control sensor based on readings from. The user interface can be configured to display in English, french, or Chinese.
Add 24 for AK, hi, or pr. C in the cold units. Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too.
All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats. There is an automated. Switch test protocol that zeros in on the. Dead-band for thermal switches. The hart scientific 9170 series metrology wells feature well depths of 203mm 8 in Fluke Calibration 9171, 9172, and. Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats.
54 in, usually at the bottom of a well. The hot units and range from. Vertical gradients in these zones range from. C over a 60mm 2.
It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source. Even without a pc, metrology wells have four different reprogrammed Calibration tasks that allow up to eight temperature set points with. Ramp and soak times between each.
C at the most commonly used temperatures to. Such performance doesn. Exist anywhere else outside of fluid baths.
For hart scientific 9170 series metrology wells, hysteresis effects range from. Temperature range from 425. F Fluke Calibration 9172-B-R-156 metrology well calibrator, 425C,w 9172-insb,w ref, 115v.
This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. For metrology wells, loading effects are minimized the same reasons that axial gradients. Any of six standard inserts may be ordered with each unit, accommodating a variety metric and imperial-sized probe diameters.
Immersion depth: depth matters. With 203mm 8 in of immersion, the Fluke Calibration 9172 significantly reduces stem conduction errors at high temperatures. The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate.
Loading effects are as minimal. Axial uniformity: the Fluke Calibration 9170 series ea document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40mm The Fluke Calibration 9172 metrology well calibrators provides temperatures from 35. C with a calibrated display accurate. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large.
For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. And we utilize proprietary dual-zone controls.
Better stability can only be found in fluid baths and primary fixed-point devices. C radial uniformity: uniformity is the difference in temperature between one well and another. New analog and digital control techniques provide stability as good.
With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance.
And with dual-zone control, axial or vertical uniformity is as good. Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.
All four model's come with an rs-232 serial interface and the model 9930, interface-it software. In addition to exceptional accuracy, the hart 9172 is stable from.
Our specs aren. Just hopes or guidelines. It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats.
Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. The Fluke Calibration 9172 only gets better with metrology wells. C, depending on temperature. This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator.
25 in diameter or smaller. C over their full range.