( Brand: Fluke Calibration ), ( Manufacturer Part Number: 9172-C-156 ), ( UPC: 095969294409 )
The Fluke Calibration 9172-INSC is a high-performance, versatile voltage source calibrator designed for metrology applications. This particular model, identified by the part number 9172-INSC 115V, is a 156-point, 0-150Vdc calibrator, suitable for use in a wide range of electrical measurement environments.
The 9172-INSC is equipped with Fluke's advanced InSight Calibration Software, which allows for easy configuration, calculation, and documentation of calibration data. The software supports a wide range of measurement standards, making it an ideal tool for metrology labs and quality assurance departments.
The calibrator features a large, high-resolution, backlit LCD display for easy reading, even in low-light conditions. It also includes a built-in USB interface for easy connection to a computer or printer, as well as a GPIB interface for automated testing and data logging.
The 9172-INSC is designed for rugged use, with a compact, lightweight design that is easy to transport. It is also equipped with overvoltage protection and a wide operating temperature range, making it suitable for use in a variety of environments.
In summary, the Fluke Calibration 9172-INSC is a high-performance, versatile voltage source calibrator that is ideal for metrology applications. Its advanced software, large display, and robust design make it an easy-to-use, reliable tool for electrical measurement and calibration.
Product: Fluke Calibration 9172-INSC with Metrology 425C, Model Number: 9172-INSC-115V-095969294409, 9172-C-156
Pros:1. High Accuracy: The Fluke Calibration 9172-INSC is known for its high accuracy, which is crucial in metrology applications.
2. Wide Temperature Range: It can operate in a wide temperature range, making it suitable for various environments.
3. Flexible Measurement Options: It offers multiple measurement options, making it versatile for various applications.
4. Durable Construction: The product is built to withstand harsh conditions, ensuring longevity and reliability.
Cons:1. High Price: The Fluke Calibration 9172-INSC is quite expensive, which may be a limiting factor for some buyers.
2. Complex Operation: Due to its advanced features, the device may have a steep learning curve for first-time users.
3. Limited Battery Life: The battery life might not be sufficient for extended use, requiring frequent recharging or replacement.
Conclusion:The Fluke Calibration 9172-INSC with Metrology 425C is a high-quality, accurate, and versatile device that is suitable for metrology applications. Its wide temperature range and multiple measurement options make it a versatile tool. However, its high price and complex operation may deter some buyers. If you can afford the investment and are willing to spend time learning how to use it, this device could be a valuable asset to your toolkit.
Recommendation:If you are in the market for a high-accuracy, multifunctional calibrator, the Fluke Calibration 9172-INSC with Metrology 425C is worth considering. Its durability and wide temperature range make it a reliable choice for various environments. However, make sure to weigh the pros and cons, and consider your specific needs and budget before making a purchase.
In addition to exceptional accuracy, the hart 9172 is stable from.
All four model's come with an rs-232 serial interface and the model 9930, interface-it software. For even better accuracy, Fluke Calibration 9172 metrology well calibrators may be ordered with built-in electronics reading external prats its-90 characterizations. Temperature range from 425. F Fluke Calibration 9172-C-156 metrology well calibrator, 425C, w 9172-insc, 115v.
Our specs aren. Just hopes or guidelines. Such performance doesn. Exist anywhere else outside of fluid baths. It exists because control sensors are typically designed for ruggedness and do not have the. Strain free. Design characteristics of sprats, or even most prats. Both low-temperature units are table to.
Display accuracy: dry-wells are typically calibrated by inserting a Prut into one of the wells and making adjustments to calibrator. ?internal control sensor based on readings from.
C in the cold units. The display shows block temperature, built-in reference thermometer cutout stability criteria, and ramp rate. Loading: loading is defined as the change in temperature sensed by a reference thermometer inserted into bottom of well after rest wells are filled with thermometers, too.
Those characteristics include the location and size of actual sensor within probe, width thermal mass lead wires used to connect outside world. Hysteresis: thermal hysteresis exists far more in internal control sensors than good-quality reference prats. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large. And we utilize proprietary dual-zone controls.
Better stability can only be found in fluid baths and primary fixed-point devices.
Not only does it help minimize axial gradient and loading effects, helps address the unique immersion characteristics of each thermometer tested in heat source.
The Fluke Calibration 9170 series metrology well calibrators uses only traceable, accredited prats to calibrate wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better specs, which range from. The Fluke Calibration 9172 metrology well calibrators provides temperatures from 35. C with a calibrated display accurate.
The Fluke Calibration 9172 only gets better with metrology wells. 25 in diameter or smaller.
Ramp and soak times between each. Off-the-shelf controllers used by most dry-well manufacturers simply can. Provide this level of performance. C at the most commonly used temperatures to.
Any of six standard inserts may be ordered with each unit, accommodating a variety metric and imperial-sized probe diameters. Vertical gradients in these zones range from. Immersion depth: depth matters.
The user interface can be configured to display in English, french, or Chinese. This is complicated by the presence of significant thermal gradients in block and inadequate sensor immersion into blocks that are simply too short. For hart scientific 9170 series metrology wells, hysteresis effects range from 0.
New analog and digital control techniques provide stability as good. All are also compatible with model 9938 met temp ii software for completely automated Calibrations of RDS, Thermopylae's, and thermostats.
C over their full range. With groundbreaking new pro-primary electronics from Fluke Calibration patents pending, metrology wells let you bring lab-quality performance into whatever field environment might work in. C, depending on temperature.
F button allows for easy switching of temperature units. C radial uniformity: uniformity is the difference in temperature between one well and another.
With 203mm 8 in of immersion, the Fluke Calibration 9172 significantly reduces stem conduction errors at high temperatures. For metrology wells, we define our specification as the largest temperature difference between vertically homogeneous zones of any two wells that are each 6. 54 in, usually at the bottom of a well.
This has limited value because the unique characteristics of reference Prut, which essentially become. Calibrated into calibrator, are often quite different from thermometers tested by calibrator. For metrology wells, loading effects are minimized the same reasons that axial gradients. The hot units and range from. There is an automated. Switch test protocol that zeros in on the. Dead-band for thermal switches.
And with dual-zone control, axial or vertical uniformity is as good. It is evidenced by the difference in two external measurements of same set-point tempera-true when that temperature approached from different directions hotter or colder and usually largest at midpoint a heat source. Add 24 for AK, hi, or pr. Loading effects are as minimal.
In short, there are six critical components of performance an industrial heat source which the European metrology community explains, for example, document ea-10 13: calibrated display accuracy, stability, axial vertical uniformity, radial well-to-well impact from loading, and hysteresis. Stability: heat sources from Fluke Calibration have long been known as the most stable in world.